Reference dose rates for single- and double-plane 192Ir implants.

C B Saw1, N Suntharalingam

  • 1Department of Radiation Oncology and Nuclear Medicine, Bodine Center for Cancer Treatment, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania 19107.

Medical Physics
|May 1, 1988
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A review on the clinical implementation of respiratory-gated radiation therapy.

Biomedical imaging and intervention journal·2011
Same author

Bilateral epidural extension of thoracic capillary vertebral (intraosseous) hemangioma mimicking spinal meningioma.

The Medical journal of Malaysia·2008
Same author

Radiation Therapy Oncology Group. Research Plan 2002-2006. Medical Physics Committee.

International journal of radiation oncology, biology, physics·2001
Same author

Experimental determination of depth-scaling factors and central axis depth dose for clinical electron beams.

International journal of cancer·2001
Same author

MLC-based IMRT-Part II.

Medical dosimetry : official journal of the American Association of Medical Dosimetrists·2001
Same author

Commissioning and quality assurance for MLC-based IMRT.

Medical dosimetry : official journal of the American Association of Medical Dosimetrists·2001
Same journal

Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

Medical physics·2026
Same journal

Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

Medical physics·2026
Same journal

Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

Medical physics·2026
Same journal

Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

Medical physics·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
See all related articles

Choosing the right reference dose rate is crucial for effective interstitial implant brachytherapy. Proper selection ensures optimal dose homogeneity within the target volume while minimizing dose to surrounding healthy tissues.

Area of Science:

  • Medical Physics
  • Radiation Oncology
  • Brachytherapy

Background:

  • Interstitial implant brachytherapy requires careful selection of the reference dose rate for optimal treatment outcomes.
  • The reference dose rate influences dose distribution, target coverage, and normal tissue sparing in brachytherapy.

Purpose of the Study:

  • To investigate the impact of reference dose rate selection on the adequacy of tumor irradiation using 192Ir interstitial implants.
  • To evaluate dose homogeneity, target coverage, and normal tissue sparing based on different reference dose rates.

Main Methods:

  • Utilized idealized target volumes for simulations of single- and double-plane 192Ir implants.
  • Employed three volumetric irradiation indices to quantify dose distribution and treatment adequacy.

Related Experiment Videos

  • Analyzed the influence of reference dose rate on dose homogeneity and spatial distribution.
  • Main Results:

    • Maximum relative dose homogeneity is achievable with the appropriate reference dose rate selection.
    • The optimal isodose rate contour shows a width exceeding the target volume's thickness in the central plane.
    • Using the lowest dose rate within the target volume as reference leads to inhomogeneous irradiation and excessive dose to surrounding tissues.

    Conclusions:

    • The reference dose rate significantly impacts the quality of dose delivery in interstitial brachytherapy.
    • Careful selection of the reference dose rate is essential for maximizing target dose homogeneity and minimizing normal tissue complication probability.
    • Avoidance of the lowest dose rate within the target volume as reference is recommended for optimal treatment planning.