Background:
The aim of the study was to derive and compare metabolic parameters relating to benign and malignant pulmonary nodules using dynamic 2-deoxy-2-[fluorine-18]fluoro-D-glucose (18F-FDG) PET/CT, and nodule perfusion parameters derived through perfusion computed tomography (CT).
Patients And Methods:
Twenty patients with 21 pulmonary nodules incidentally detected on CT underwent a dynamic 18F-FDG PET/CT and a perfusion CT. The maximum standardized uptake value (SUVmax) was measured on conventional 18F-FDG PET/CT images. The influx constant (K ) was calculated from the dynamic 18F-FDG PET/CT data using Patlak model. Arterial flow (AF) using the maximum slope model and blood volume (BV) using the Patlak plot method for each nodule were calculated from the perfusion CT data. All nodules were characterized as malignant or benign based on histopathology or 2 year follow up CT. All parameters were statistically compared between the two groups using the nonparametric Mann-Whitney test.
Results:
Twelve malignant and 9 benign lung nodules were analysed (median size 20.1 mm, 9-29 mm) in 21 patients (male/female = 11/9; mean age ± SD: 65.3 ± 7.4; age range: 50-76 years). The average SUVmax values ± SD of the benign and malignant nodules were 2.2 ± 1.7 vs. 7.0 ± 4.5, respectively (p = 0.0148). Average K values in benign and malignant nodules were 0.0057 ± 0.0071 and 0.0230 ± 0.0155 min-1, respectively (p = 0.0311). Average BV for the benign and malignant nodules were 11.6857 ± 6.7347 and 28.3400 ± 15.9672 ml/100 ml, respectively (p = 0.0250). Average AF for the benign and malignant nodules were 74.4571 ± 89.0321 and 89.200 ± 49.8883 ml/100g/min, respectively (p = 0.1613).
Conclusions:
Dynamic 18F-FDG PET/CT and perfusion CT derived blood volume had similar capability to differentiate benign from malignant lung nodules.
More Related Videos
10:04Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET