Test-retest reliability and validity of body composition methods in adults
Julia O Totosy de Zepetnek1, Jennifer J Lee2, Terence Boateng2
1Faculty of Kinesiology and Health Studies, University of Regina, Regina, SK, Canada.
Abstract:
Cost-effective and efficient body composition measurement devices that are reliable and valid are necessary for identifying health risk as well as for understanding the effectiveness of lifestyle interventions. The objective of this study was to evaluate the test-retest reliability and validity of three body composition measurement devices. Forty-nine adults (mean age (SD) = 31.5 (10.7) y; BMI = 23.5 (3.0) kg/m2 ) completed a reference air displacement plethysmography (ADP) measure, and duplicate measures using skinfold callipers (Lange), ultrasound (BodyMetrix A-mode) and a 3-dimensional photonic scanner (3DPS; Fit3D ProScanner). Skinfold thickness was measured at seven sites using callipers and ultrasound; percent body fat (%BF) was then estimated using population-specific algorithms. The 3DPS was used to measure body circumferences, and then %BF was estimated using its beta-software. While skinfold callipers showed poor absolute reliability (mean differences (Δ) [95% CI] = 0.54% [0.22, 0.87], standard error of measurement (SEM) = 0.63%), ultrasound and the 3DPS showed excellent absolute (Δ = 0.17% [-0.25, 0.58], SEM = 0.78%; and Δ = -0.01% [-0.43, 0.40], SEM = 0.67%, respectively) and relative reliability (ICC2,1 = 0.988 [0.979, 0.993]; and ICC2,1 = 0.983 [0.968, 0.991], respectively). Compared to ADP (n = 43), skinfold callipers underestimated %BF (Δ = -4.53 [-7.72, -1.34]; p = 0.003), while ultrasound (Δ = -0.32 [-3.51, 2.87]; p = 0.99) and the 3DPS (Δ = 1.06 [-2.12. 4.26]; p = 0.77) were not significantly different. Bland-Altman plots showed a minimal bias of ultrasound [95% limit of agreement (LOA) = -7.87, 7.23] and the 3DPS [95% LOA = -6.66, 8.79]. In conclusion, estimating %BF from subcutaneous fat measurements using ultrasound and body circumferences using a 3DPS may be reliable and valid methods that require minimal technician expertise.
More Related Videos
06:48Author Spotlight: Advancements in 3D Optical Imaging for Comprehensive Body Composition Assessment in Modern Research
Published on: June 7, 2024
07:44Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023