Related Experiment Video
Updated: Nov 3, 2025

Cultivating a Three-dimensional Reconstructed Human Epidermis at a Large Scale
Published on: May 28, 2021
Validation study of a new reconstructed human epidermis model EPiTRI for in vitro skin irritation test according to
Chih-Ching Liao1, Cheng-Yi Wu1, Meng-Hsueh Lin1
1Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute (ITRI), Taiwan, ROC.
Abstract:
Following the global trend of reducing animal testing, various reconstructed human epidermis (RHE) models for skin irritation test (SIT) have been developed, verified, validated and included in OECD TG 439. We developed a new RHE called EPiTRI and a SIT method using EPiTRI (EPiTRI-SIT model) following the OECD guidelines. EPiTRI possesses morphological, biochemical and physiological properties similar to human epidermis with well-differentiated multilayered viable cells with barrier function. The EPiTRI-SIT model was tested for 20 reference chemicals in Performance Standard of OECD TG 439 (GD 220), showing good predictive capacity with 100% sensitivity, 70% specificity and 85% accuracy. EPiTRI had sensitivity in detecting di-n-propyl disulphate, as an irritant chemical (UN GHS Category 2), whereas most validated reference methods detected it as a non-irritant. An international validation study of EPiTRI-SIT was conducted in four laboratories to confirm the within- and between-laboratory reproducibility, as well as predictive capacity. The phase I/II within-laboratory and between-laboratory reproducibility was 100%/95% and 95%, respectively. The overall sensitivity, specificity and accuracy of EPiTRI-SIT was 96%, 70% and 83%, respectively, which fulfilled the OECD criteria. Thus, EPiTRI, meets the criteria of Performance Standards of OECD TG 439 (GD 220) and is suitable for screening irritating chemicals in vitro.
More Related Videos
21:16An In Vitro Skin Irritation Test SIT using the EpiDerm Reconstructed Human Epidermal RHE Model
Published on: July 13, 2009
10:13Eye Irritation Test EIT for Hazard Identification of Eye Irritating Chemicals using Reconstructed Human Cornea-like Epithelial RhCE Tissue Model
Published on: August 23, 2015
Related Concept Videos
Clinical Applications of Epidermal Stem Cells
Renewal of Skin Epidermal Stem Cells