Related Experiment Video
Updated: Nov 3, 2025

10:32
Fabrication of Uniform Nanoscale Cavities via Silicon Direct Wafer Bonding
Published on: January 9, 2014
7.9K
Wafer-Bonding Fabricated CMUT Device with Parylene Coating
Changde He1,2,3, Binzhen Zhang3, Chenyang Xue3
1School of Electronic and Computer Engineering, Peking University, Shenzhen 518055, China.
Micromachines
|June 2, 2021
Summary
This study introduces a novel capacitive micromachined ultrasound transducer (CMUT) for low-frequency underwater imaging. The fabricated CMUT demonstrates effective ultrasound transmission and reception, paving the way for new underwater imaging technologies.
Area of Science:
- Materials Science
- Electrical Engineering
- Acoustics
Background:
- Capacitive micromachined ultrasound transducer (CMUT) technology has driven advances in medical ultrasound imaging.
- Standard silicon IC fabrication limits CMUT development for low-frequency underwater applications due to difficulties in creating thick membranes.
- Existing CMUT research predominantly focuses on high-frequency medical uses, neglecting low-frequency underwater potential.
Purpose of the Study:
- To propose and fabricate a novel CMUT device suitable for low-frequency underwater imaging applications.
- To overcome fabrication challenges associated with thick membrane structures in standard IC processes.
- To demonstrate the feasibility of CMUTs for underwater acoustic sensing.
Main Methods:
- Fabrication of a CMUT device featuring a 2.83-μm thick silicon membrane using silicon fusion wafer-bonding technology.
- Conformal deposition of a 5-μm thick Parylene-C layer for immersion measurement.
- Characterization of the CMUT's ultrasound transmission, reception, and pulse-echo capabilities.
Main Results:
- The fabricated CMUT successfully transmitted and received ultrasound waves, exhibiting pulse-echo measurement capability.
- The device's ultrasonic emission and reception performance improved with increasing bias voltage, independent of polarity.
- The results validate the CMUT's suitability for low-frequency applications, considering its structure, fabrication, and performance.
Conclusions:
- The developed CMUT technology shows significant potential for advancing underwater ultrasound imaging.
- Silicon fusion wafer-bonding offers a viable method for fabricating thick-membrane CMUTs for low-frequency applications.
- This research opens new avenues for CMUT utilization in diverse underwater acoustic sensing scenarios.
Keywords:
Parylenecapacitive micromachined ultrasound transducer (CMUT)fusion bondingmicromachinepulse-echo signaltransducerunderwater imaging