Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Discovery, Optimization, and Evaluation of Potent and Selective PDGFRβ Inhibitors for the Treatment of Hepatocellular Carcinoma.

Journal of medicinal chemistry·2026
Same author

A field-deployable high-resolution SNP genotyping platform for rapid surveillance of <i>Yersinia pestis</i>.

Virulence·2026
Same author

CBAM meets DropBlock: enhancing robot steering-angle prediction with hybrid attention and structured dropout.

Scientific reports·2026
Same author

Synergizing Strain and Ternary Components in Ultrathin PtCuIr-IrO<sub><i>x</i></sub> Nanodendrites to Enable the C<sub>2</sub> Pathway for Ethanol Electrooxidation.

Inorganic chemistry·2026
Same author

Phase separation of p85β modulates hepatocellular carcinoma progression through POLR1A.

International journal of biological sciences·2026
Same author

A cascade-responsive nanoplatform for cyclooxygenase-2 inhibition and inflammation regulation to enhance photoimmunotherapy.

Acta biomaterialia·2026

Related Experiment Video

Updated: Nov 3, 2025

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

21.4K

Modular and Self-Contained Microfluidic Analytical Platforms Enabled by Magnetorheological Elastomer Microactuators.

Yuxin Zhang1, Tim Cole1, Guolin Yun2

  • 1Department of Electronic, Electrical and Systems Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT, UK.

Micromachines
|June 2, 2021
PubMed
Summary
This summary is machine-generated.

This study introduces a novel microfluidic chip using magnetorheological elastomer actuators for portable diagnostics. This lab-on-a-chip system eliminates external connections and complex fabrication for point-of-care testing.

Keywords:
actuatorslab-on-a-chipmagnetorheological elastomermicrofluidicsself-contained system

More Related Videos

Aqueous Droplets Used as Enzymatic Microreactors and Their Electromagnetic Actuation
08:27

Aqueous Droplets Used as Enzymatic Microreactors and Their Electromagnetic Actuation

Published on: August 28, 2017

5.5K
Electrowetting-based Digital Microfluidics Platform for Automated Enzyme-linked Immunosorbent Assay
08:22

Electrowetting-based Digital Microfluidics Platform for Automated Enzyme-linked Immunosorbent Assay

Published on: February 23, 2020

9.8K

Related Experiment Videos

Last Updated: Nov 3, 2025

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

21.4K
Aqueous Droplets Used as Enzymatic Microreactors and Their Electromagnetic Actuation
08:27

Aqueous Droplets Used as Enzymatic Microreactors and Their Electromagnetic Actuation

Published on: August 28, 2017

5.5K
Electrowetting-based Digital Microfluidics Platform for Automated Enzyme-linked Immunosorbent Assay
08:22

Electrowetting-based Digital Microfluidics Platform for Automated Enzyme-linked Immunosorbent Assay

Published on: February 23, 2020

9.8K

Area of Science:

  • Biomedical Engineering
  • Materials Science
  • Microfluidics

Background:

  • Current point-of-care (POC) diagnostics face limitations in portability and cost due to complex microfabrication and bulky equipment.
  • Microfluidic technology's potential is often restricted to laboratory settings, limiting its application in real-world diagnostic scenarios.

Purpose of the Study:

  • To develop a self-contained, insert-and-use microfluidic device for image-based analysis.
  • To overcome the limitations of traditional microfluidic platforms by eliminating external connections and simplifying fabrication.

Main Methods:

  • Integration of magnetorheological elastomer (MRE) microactuators (pumps, mixers, valves) into a modular microfluidic chip without microfabrication.
  • Development of novel manipulation principles for MRE-based microfluidic control.
  • Design of a driving and controlling platform for chip insertion and operation.

Main Results:

  • Demonstration of a self-contained microfluidic system capable of sample preparation and sequential pumping.
  • Validation of the MRE-enabled microfluidic platform's ability to perform insert-and-use image-based analysis.
  • Confirmation of straightforward fabrication, low cost, and rapid chip reconfiguration.

Conclusions:

  • The MRE-enabled microfluidic platform offers a robust and versatile solution for integrated lab-on-a-chip systems.
  • This technology enhances the portability and reduces the cost of microfluidic devices for point-of-care diagnostics.
  • The novel approach facilitates broader application of microfluidics outside traditional laboratory environments.