Related Experiment Video
Updated: Nov 3, 2025

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Dynamic Indices Fail to Predict Fluid Responsiveness in Patients Undergoing One-Lung Ventilation for Thoracoscopic
Kwan-Hoon Choi1, Jae-Kwang Shim2, Dong-Wook Kim1
1Department of Anesthesiology and Pain Medicine, Wonju College of Medicine, Yonsei University, Wonju 26426, Korea.
Abstract:
Thoracic surgery using CO2 insufflation maintains closed-chest one-lung ventilation (OLV) that may provide the necessary heart-lung interaction for the dynamic indices to predict fluid responsiveness. We studied whether pulse pressure variation (PPV) and stroke volume variation (SVV) can predict fluid responsiveness during thoracoscopic surgery. Forty patients were enrolled in the study. OLV was performed with a tidal volume of 6 mL/kg at a positive end-expiratory pressure of 5 cm H2O, while CO2 was insufflated to the contralateral side at 8 mm Hg. Patients whose stroke volume index (SVI) increased ≥15% after fluid challenge (7 mL/kg) were defined as fluid responders. The predictive ability of PPV and SVV on fluid responsiveness was investigated using the area under the receiver-operator characteristic curve (AUROC), which was also assessed according to the right or left lateral decubitus position considering the intrathoracic location of the right-sided superior vena cava. AUROCs of PPV and SVV for predicting fluid responsiveness were 0.65 (95% confidence interval 0.47-0.83, p = 0.113) and 0.64 (95% confidence interval 0.45-0.82, p = 0.147), respectively. The AUROCs of indices did not exhibit any statistical significance according to position. Dynamic indices of preload cannot predict fluid responsiveness during one-lung ventilation with CO2 gas insufflation.
More Related Videos
05:56Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...