Visual-afterglow dual-mode immunochromatographic strip for 17β-estradiol detection in milk
Yi Zhang1, Lingling Wang1, Wen-Long Wang1
1State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, Jiangsu, China; International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, 214122, Jiangsu, China; Institute of Analytical Food Safety, School of Food Science and Technology, Jiangnan University, Wuxi, 214122, Jiangsu, China.
Abstract:
The continuous intake of 17β-estradiol (E2) residue from animal-derived food may pose a threat to the health of consumers, so the rapid screen and detection of E2 is very necessary. Although visual immunochromatographic strip (ICS) has played a great role in food safety control such as the screen of many food contaminants, it cannot meet the requirements for E2 detection due to the insufficient sensitivity of traditional visual ICS and the low concentration range of estrogen in food. Here, we developed a dual-mode ICS strategy to achieve rapid and highly sensitive detection of E2. Based on the visual detection mode of a competitive ICS, the afterglow detection mode working in fluorescence resonance energy transfer mechanism was introduced by using the afterglow particles (APs) as energy donor and gold nanoparticles (AuNPs) as energy acceptor. In this method, large APs of micron size with superior afterglow were applied as the test zone-fixed fluorescence signal source, thus the contradiction between migration and afterglow characteristics was skillfully resolved. In addition, a 6 W UV lamp was used as the light source to excite APs, and a smartphone was used to capture an image of 0.5 s after the UV light was turned off to effectively remove the autofluorescence from the strips and improve the signal-to-noise ratio. The limit of detection of this afterglow mode was 0.5 ng/mL, twenty times more sensitive than that of visual mode (10 ng/mL). The strategy has been successfully applied to the detection of estradiol in milk and verified by HPLC-FLD.
More Related Videos
10:10Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
05:25Author Spotlight: Expanding the Scope of Multiplex Immunoassays for Lyme Borreliosis Diagnostics and Pathogen Research
Published on: July 14, 2023