Related Experiment Video
Updated: Nov 3, 2025

Use of Enzymatic Biosensors to Quantify Endogenous ATP or H2O2 in the Kidney
Published on: October 12, 2015
Translating potentiometric detection into non-enzymatic amperometric measurement of H2O2
Tanji Yin1, Hemin Wang2, Jinghui Li1
1Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Provincial Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai Shandong, 264003, PR China; Laboratory for Marine Biology and Biotechnology, Pilot National Laboratory for Marine Science and Technology, Qingdao, 26620, PR China; Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, Shandong, 266071, PR China.
Abstract:
The developments of alternative signal readout strategies for the ion-selective electrodes (ISEs) are necessary in order to break through the limitation of the Nernst equation. In this work, a simple, convenient and easily operated strategy based on the non-enzymatic amperometric measurement of H2O2 is proposed to read out the potentiometric responses for the ISEs. The proposed amperometric signal readout based on H2O2 is carried out in a two compartment electrochemical cell configuration containing a detection cell and a sample cell, physically connected by a salt bridge. A glassy carbon (GC) electrode is placed in the detection cell to monitor the oxidation current of H2O2, and an ISE is placed in the sample cell to act as both the reference electrode and the potentiometric sensor for obtaining the ion activities. The oxidation of H2O2 is induced by a constant potential applied between the GC electrode and the ISE, and subsequently modulated by the potential change of the ISE in the presence of the primary ion. The proposed amperometric signal readout based on H2O2 shows the satisfied slope sensitivity and detection limit, which are better than or compared to those for the potentiometric responses for the ISEs. This work provides a general strategy for transforming the potential response of the ISEs into the amperometric readout, and is promising for detection of cations (eg., Ca2+) and anions (eg., NO3-) with high sensitivity and excellent selectivity.
Related Concept Videos
Potentiometry: Overview
Amperometry: Overview
Potentiometry: Membrane Electrodes
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometric Titration: Overview

