Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

7.4K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.4K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

111
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
111
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT01:25

Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

184
Calcium-Scoring CT ScanA calcium-scoring CT scan, also known as coronary artery calcium (CAC) scan, detects calcium deposits in the coronary arteries. This test assesses the risk of coronary artery disease (CAD), which can lead to cardiovascular events such as angina, heart failure, and sudden cardiac arrest.A calcium-scoring CT scan is generally recommended for individuals at intermediate risk of CAD without symptoms. It includes:Men aged 40-75 and women aged 50-75: Especially those with a...
184
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

2.6K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.6K
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

122
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
122

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Enantioselective Radical Ring-Opening Cyanation of Oxime Esters by Dual Photoredox and Copper Catalysis.

Organic letters·2019
Same author

ACCELERATING MAGNETIC RESONANCE IMAGING VIA DEEP LEARNING.

Proceedings. IEEE International Symposium on Biomedical Imaging·2019
Same author

Technical note: Development and application of KASP assays for rapid screening of 8 genetic defects in Holstein cattle.

Journal of dairy science·2019
Same author

Sesquiterpenes and diterpenes from Euphorbia thymifolia.

Fitoterapia·2019
Same author

Glechomanamides A-C, Germacrane Sesquiterpenoids with an Unusual Δ<sup>8</sup>-7,12-Lactam Moiety from <i>Salvia scapiformis</i> and Their Antiangiogenic Activity.

Journal of natural products·2019
Same author

Parameter optimization framework on wave gradients of Wave-CAIPI imaging.

Magnetic resonance in medicine·2019

Related Experiment Video

Updated: Nov 3, 2025

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

500

PWLS-PR: low-dose computed tomography image reconstruction using a patch-based regularization method based on the

Jing Fu1,2, Fei Feng3, Huimin Quan2

  • 1Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.

Quantitative Imaging in Medicine and Surgery
|June 3, 2021
PubMed
Summary

This study introduces a new patch-based method for low-dose computed tomography (CT) scans. The penalized weighted least squares total variation (PWLS-PR) algorithm improves image quality and reduces radiation exposure risks.

Keywords:
Lose-dose computed tomography (lose-dose CT)image reconstructionpatch regularizationpenalized weighted least squares (PWLS)total variation (TV)

More Related Videos

Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
06:57

Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection

Published on: September 22, 2023

1.2K
3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
07:01

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography

Published on: October 24, 2019

10.0K

Related Experiment Videos

Last Updated: Nov 3, 2025

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

500
Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
06:57

Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection

Published on: September 22, 2023

1.2K
3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
07:01

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography

Published on: October 24, 2019

10.0K

Area of Science:

  • Medical Imaging
  • Radiology
  • Image Reconstruction

Background:

  • Computed tomography (CT) scans pose radiation exposure risks.
  • Low-dose CT imaging can reduce radiation but may introduce noise and artifacts.
  • Traditional filtered back projection (FBP) struggles with low-dose data quality.

Purpose of the Study:

  • To develop an iterative image reconstruction method for high-quality low-dose CT.
  • To introduce a patch-based regularization for enhanced noise and artifact reduction.
  • To improve the robustness of image reconstruction in CT.

Main Methods:

  • Proposed a patch-based regularization method: penalized weighted least squares total variation (PWLS-PR).
  • Utilized neighborhood patches for nonquadratic penalty calculation, enhancing robustness.
  • Employed a three-step iterative process: PWLS-TV updating, smoothing, and pixel fusion.

Main Results:

  • The PWLS-PR algorithm demonstrated superior image reconstruction performance compared to existing methods.
  • Both simulation and real-world experiments confirmed the algorithm's effectiveness.
  • Qualitative and quantitative evaluations validated the proposed method's capabilities.

Conclusions:

  • The PWLS-PR method effectively reduces noise and artifacts in low-dose CT images.
  • It requires less projection data, enabling fewer CT scans.