The role of fretting-frequency on the damage modes of THR modular junction: In-vitro study
Bartlomiej Radzik1, Divya Bijukumar1, Kai-Yuan Cheng2
1Regenerative Medicine and Disability Research (RMDR) Lab, Department of Biomedical Sciences, UIC College of Medicine at Rockford, IL, United States of America.
Abstract:
According to the National Center for Health Statistics, currently, more than 250,000 total hip replacements annually in the US alone, with an estimated increase to 500,000 by the year 2030. The usage of tapered junctions between the femoral neck and head gives the surgeon flexibility in implant assembly. However, these modular junctions are subjected to micro-motion that may cause chemical and fretting-corrosion at the modular junction. Therefore, it is imperative to study these forces to mitigate their effects. The current study aims to understand the effects of fretting-corrosion as a function of fretting frequencies caused by common physical activities in an in-vitro model of hip modular junctions. The fretting system has a tribological contact condition of flat-on-flat, mounted to a load frame. CoCrMo pins were polished and immersed in a synovial fluid-like electrolyte solution (Bovine calf serum 30 g/l). Electrochemical measurements were made using a potentiostat. Samples then undergo 3600 cycles at 50 μm (to simulate gross slips), with a horizontal load at 200 N, and a frequency of 0.5 Hz, 0.7 Hz, 1 Hz, and 1.5 Hz to simulate Sit Down-Stand Up, Stair Climb, Walking, and Jogging, respectively. Worn surfaces were then examined under optical and scanning electron microscopy. The evolution of free potential as a function of time for tested frequencies shows the initial potential drop and stabilized trend in the potential evolution. The sample group at a higher frequency displays a higher tendency of corrosion than a lower frequency; however, the dissipation energy decreases as a function of fretting frequency. Both electrochemical and mechanical responses correlate to the variation in the fretting frequencies. Organometallic complexes were found on the surfaces of the samples that were subjected to a slower frequency of fretting, whereas mechanical grooving was noticed on samples with a faster frequency. Hence, these preliminary studies suggest that implant failure rates may be altered based on fretting-frequencies induced by physical activity. Further studies will be required to verify the findings and explore the potential role of fretting frequency in the damage modes of the modular junction.
More Related Videos
11:10Dissecting Cell-Autonomous Function of Fragile X Mental Retardation Protein in an Auditory Circuit by In Ovo Electroporation
Published on: July 6, 2022
09:45Author Spotlight: Studying Biomechanics of Circulating Cells by Modulating Their Electrodeformation Behavior
Published on: October 13, 2023
Related Concept Videos
Frequency Response of a Circuit
The transfer function is pivotal in characterizing how these circuits react to various frequencies, facilitating a profound understanding of their behavior. An essential parameter is the time constant, signifying the...
Biasing of Metal-Semiconductor Junctions
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
Biasing of FET
In an N-channel JFET, the structure consists of N-type material forming the channel on a P-type substrate, with the...
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Types of Damping
Frequency Response of BJT
Low-Frequency Response: At low frequencies, the behavior of the BJT is determined by its DC bias point, which is set by the...