Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay
Mahmoud Jabbarvand1, Mehdi Khodaparast1, Alireza Jamali2
1Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran.
Purpose:
To investigate the changes in the optical corneal densitometry as an objective method in assessing the corneal light back-scattering before and 1 year after the annular intracorneal inlay (AICI) implantation into the keratoconic corneas.
Methods:
Changes in the optical corneal densitometry, visual acuity, refractive, and tomographical status were assessed before and 1 year after the AICI implantation into the corneas with different stages of keratoconus. Optical corneal densitometry was evaluated using the Pentacam-HR in 0-2, 2-6, 6-10, and 10-12 mm rings in the anterior 120 μ, central layers, posterior 60 μ and also the total value were measured for cornea in the Grey Scale Unit criterion.
Results:
Totally, 34 patients with keratoconus were studied; the uncorrected and best corrected visual acuity were increased after the surgery (0.98 ± 0.25 to 0.53 ± 0.30 logMAR, P < 0.001 and 0.26 ± 0.18 to 0.19 ± 0.14, P = 0.007 logMAR, respectively); the spherical equivalent was decreased from -4.45 ± 2.25 to - 2.06 ± 2.01 D (P = 0.004). AICI implantation led to an increase in the amount of optical corneal densitometry in 0-2 mm central, 2-6 mm central, 6-10 mm central, total central, 2-6 mm posterior, and 2-6 mm total rings (all, P < 0.05); however, a decrease was observed in 0-2 mm anterior ring (P = 0.049). Results of statistical analysis showed that the total optical corneal densitometry, anterior total, and posterior total back-scattering did not change after the AICI implantation (all, P > 0.05).
Conclusions:
Our results revealed a significant improvement in the visual function, including refractive error and visual acuity following the AICI implantation. Changes in the optical corneal densitometry were different in distinct regions and layers however, the total amount did not change after the AICI implantation.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview