Learning and non-learning algorithms for cuffless blood pressure measurement: a review
Nishigandha Dnyaneshwar Agham1, Uttam M Chaskar2
1College of Engineering Pune, Wellesely Rd, Pune, 411005, India. nishi1012@gmail.com.
Abstract:
The machine learning approach has gained a significant attention in the healthcare sector because of the prospect of developing new techniques for medical devices and handling the critical database of chronic diseases. The learning approach has potential to analyze complex medical data, disease diagnosis, and patient monitoring system, and to monitor e-health record. Non-invasive cuffless blood pressure (CLBP) measurement secured a significant position in the patient monitoring system. From a few recent decades, the importance of cuffless technology has been perceived towards continuous monitoring of blood pressure (BP) and supplementary efforts have been made towards its continuous monitoring. However, the optimal method that measures BP unambiguously and continuously has not yet emerged along with issues like calibration time, accuracy and long-term estimation of BP with miniaturizing hardware. The present study provides an insight into several learning algorithms along with their feature selection models. Various challenges and future improvements towards the current state of machine learning in healthcare industries are discussed in the present review. The bottom line of this study is to provide a comprehensive perspective of the machine learning approach of CLBP for the generation of highly precise predictive models for continuous BP measurement.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.