The solvation parameter model is used for the selectivity evaluation of siloxane-bonded reversed-phase columns with mobile phases containing from 20-70 % (v/v) acetone-water. System constants determined at 10 % (v/v) increments of acetone solvent were utilized for the construction of system maps and correlation diagrams on five columns with different stationary phase chemistry; superficially porous octadecylsiloxane-bonded silica (Kinetex C18), electrostatic-shielded octadecylsiloxane-bonded silica (Luna Omega PS C18, diisobutyloctadecyl-bonded silica(Kinetex XB-C18), phenylhexyl-bonded silica (Kinetex Phenyl-Hexyl) and octylsiloxane-bonded silica (Kinetex C8). For all columns and acetone-water compositions the calibration n = 34 to 39 had a range for the coefficient of determination from 0.988 to 0.998, Fisher statistic from 277 to 1551 and a standard error of the estimate from 0.024 to 0.097. A comparison of the system constants for acetonitrile and methanol compositions for the same separation conditions confirms that the general solvation properties of acetone mobiles phases are more similar to that of acetonitrile than methanol and that method transfer should not be difficult.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
09:08Separation of Aldehydes and Reactive Ketones from Mixtures Using a Bisulfite Extraction Protocol
Published on: April 2, 2018
Related Concept Videos
Analyte Adsorption and Distribution
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Titration in Nonaqueous Solvents
Entropy and Solvation
Solvating Effects
Leveling Effect and Non-Aqueous Acid-Base Solutions
The Leveling Effect of a Solvent
A generic acid (HA) reacts with the generic base (B-) to yield the corresponding conjugate base (A-) and conjugate acid (HB):