Related Experiment Video
Updated: Nov 3, 2025

Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
ACURATE neo™ aortic valve implantation via carotid artery access: first case report
Chadi Aludaat1, Alexandre Canville2, Quentin Landolff2
1Department of Cardiac Surgery, Heart Team Unit, Rouen University Hospital, Hôpital Charles Nicolle, F76000, Rouen, France. chadi.aludaat@chu-rouen.fr.
Background:
The ACURATE neo™ transcatheter heart valve (Boston Scientific, Marlborough, Massachusetts) is predominantly implanted via femoral access. Transcarotid use of this prothesis has never been reported.
Case Presentation:
We present the case of an 89-year-old woman referred to us for a transcatheter aortic valve replacement (TAVR). After apparatus imaging of the aortic annulus and the peripheral vascular pathway, the heart team was confronted with a triple challenge: (i) The preferable choice of a self-expanding valve because of a small aortic annulus in an obese woman. (ii) Gaining favorable access to the coronary ostia, considering multiple recent coronary stenting. (iii) Utilizing an alternative arterial access because of iliac and femoral severely calcified stenosis. Implanting the ACURATE neo™ transcatheter heart valve (THV) via carotidal access allowed us to overcome these challenges. The procedure was performed successfully without any short-term complications.
Conclusion:
We report the first case of implantation of an ACURATE neo™ transcatheter heart valve (Boston Scientific, Marlborough, Massachusetts) via the right common carotid artery.