The interactions between chiral analytes and chitosan-based chiral stationary phases during enantioseparation
Wei Chen1, Ji-Zhou Jiang2, Guo-Song Qiu1
1School of Chemistry and Environmental Engineering, China.
Abstract:
The goal of the present study was to disclose the interactions between chitosan-type chiral selectors (CSs) and chiral analytes during enantioseparation. Hence, six chitosan 3,6-bis(phenylcarbamate)-2-(cyclohexylmethylurea)s were synthesized and characterized. These chitosan derivatives were employed as CSs with which the corresponding coated-type chiral stationary phases (CSPs) were prepared. According to the nature and position of the substituents on the phenyl group, the CSs and CSPs were divided into three sets. The counterparts of the three sets were 3,5-diMe versus 3,5-diCl, 4-Me versus 4-Cl and 3-Me versus 3-Cl. The enantioseparation capability of the CSPs was evaluated with high-performance liquid chromatography. The CSPs demonstrated a good enantioseparation capability to the tested chiral analytes. In enantioselectivity, the CSs with 3,5-diCl and with 4-Me roughly were better than the counterparts with 3,5-diMe and with 4-Cl respectively. The CS with 3-Me enantiomerically recognized more analytes than the one with 3-Cl, but showed lower separation factors in more enantioseparations. The acidity of the amide hydrogen in the phenylcarbamates was investigated with density functional theory calculations and 1H NMR measurements. The trend of the acidity variation with different substituents on the phenyl group was confirmed by the retention factors of acetone on the CSPs. Compared the retention factors of analytes on every set of the counterparts, the formation of hydrogen bond (HB) in enantioseparation could be outlined as follows: when the CSs interacted with chiral analytes without reactive hydrogen but with lone paired electrons, the carbamate N‒Hs in the CSs were HB donors and the analytes were HB acceptors; if the CSs interacted with analytes with a reactive hydrogen, the role of the CSs in HB formation was related to the acidity of the reactive hydrogen; the patterns of HB formation between the CSs and analytes were also impacted by compositions of mobile phases, in addition to the nature, number and position of substituents on the phenyl group. Based on the discussion, chiral recognition mechanism could be understood in more detail. Besides, the strategy to improve enantioseparation capability of a CSP by introducing a substituent onto phenyl group was clarified and further comprehended.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Analyte Adsorption and Distribution
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...