Dataset on capability of suppressing background noise and anti-tilting of divided-aperture differential confocal Raman microscopy system
Related Experiment Video
Updated: Nov 2, 2025

Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
Yunhao Su1, Ruirui Zhang1, Hanxu Wu1
1Beijing Key Laboratory for Precision Optoelectronic Measurement Instrument and Technology, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China.
Abstract:
The dataset describes the mechanism of suppressing the background noise of the divided-aperture differential confocal Raman microscopy system and the range of tilting angles that the system can handle. On the basis of the confocal microscopy (CM), the divided-aperture confocal microscopy divided the pupil plane of the objective lens into the illumination pupil and collection pupil. Compared with the CM, the divided-aperture confocal microscopy only changes the pupil parameters, according to the partially coherent imaging theory, we simulate and analyze the axial response curves of the divided-aperture confocal system and the traditional confocal system. We also simulated the differential confocal response curve at different tilting angles and get the data for the applicability of the differential confocal response curve to see if there is a single zero-crossing point or a good linearity near the zero-crossing point. The goodness-of-fit (GOF) is used to evaluate the accuracy of linear fitting, and can be used as a simple measure method of linearity. And the closer the GOF value is to 1, the higher fitting accuracy is. Through simulation analysis, we can have a better understanding of the advances of divided-aperture differential confocal Raman microscopy.
More Related Videos
Related Concept Videos
Confocal Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...