Analytical comparison of ELISA and mass spectrometry for quantification of serum hepcidin in critically ill patients
Related Experiment Video
Updated: Nov 2, 2025

Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
Constance Delaby1,2, Jérôme Vialaret1, Christophe Hirtz1
1INM, Université de Montpellier, INSERM, CHU Montpellier, IRMB, Laboratoire de Biochimie Protéomique, Montpellier, France.
Abstract:
Aim: To compare methods of quantifying serum hepcidin (based on MS and ELISA) and their ability to diagnose true iron deficiency anemia in critically ill patients. Materials & methods: Serum hepcidin was measured in 119 critically ill patients included in the HEPCIDANE clinical trial, using either an ultra-sensitive ELISA kit (from DRG) or two different MS methods. Results: The results show a good correlation between the different methods studied. The Bland-Altman analysis and the Kappa test for clinical groups show a good or very good agreement between the different tests. Conclusion: ELISA or MS show a satisfactory commutability to quantify serum hepcidin. This is of great importance for the determination of therapeutic strategies in iron deficiency.