Related Experiment Video
Updated: Nov 2, 2025

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Placement of finger oximeter on the ear: comparison with oxygen saturation values taken from the finger
Joanna Shakespeare1, Edward Parkes2, Catherine Gilsenan3
1Clinical Scientist and Service Manager, Department of Respiratory Medicine, University Hospitals Coventry and Warwickshire, Coventry.
Abstract:
Pulse oximetry is widely used to assess oxygen saturation (SpO2) in order to guide patient care and monitor the response to treatment. However, inappropriate oximeter probe placement has been shown to affect the measured oximetry values in healthy and normoxic outpatients. This study evaluated how treatment decisions might be impacted by SpO2 values obtained using a finger probe placed on the pinna of the ear in a cohort of 46 patients receiving non-invasive ventilation compared with values obtained from a probe on the finger and the results of arterial blood gas (ABG) (SaO2) analysis. Bland-Altman analysis was performed to evaluate agreement between the methods. Finger probe saturation was not statistically different from SaO2, with a mean difference of -0.66% (P>0.05). Saturation from the ear was significantly different (-4.29%; P<0.001). Subgroup analysis in hypoxic patients (SaO2<90%) showed a significant difference between ABG SaO2, and finger and ear SpO2. The study provides evidence that placement of a finger probe on the ear is unsafe clinical practice, potentially leading to patient mismanagement.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Transport in the Blood
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...