Related Experiment Video
Updated: Nov 2, 2025

Measuring the Complete-arch Distortion of an Optical Dental Impression
Published on: May 30, 2019
Distortion or magnification? An in vitro cone-beam CT study of dimensional changes of objects with different
Fernanda Coelho-Silva1, Hugo Gaêta-Araujo2, Lucas P Lopes Rosado1
1Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil.
Objectives:
To assess whether dimensional changes occur as shape distortion (unevenly), contraction or magnification (evenly) in cone beam computed tomography (CBCT) considering materials, anatomical regions and metal artefact reduction algorithms.
Methods:
Four cylinders of amalgam (Am), cobalt-chromium (Co-Cr), gutta-percha (Gu), titanium (Ti) and zirconium (Zi) were inserted inside a polymethylmethacrylate phantom in anterior and posterior regions for acquisitions in Picasso Trio and OP300 with MAR enabled and disabled. Two observers measured the dimensions of each cylinder in three axes: Y (height), Z (antero posterior diameter) and X (latero-lateral diameter). Repeated measures ANOVA with Tukey post-hoc test compared the data (α = 5%).
Results:
Shape distortion occurred for all materials in anterior region of Picasso Trio without MAR (p < 0.05). With MAR enabled, Gu and Ti contracted (p ≥ 0.05), while the others showed distortion (p < 0.05). In posterior region, all materials distorted in both MAR conditions (p < 0.05), except Gu, which magnified without MAR (p ≥ 0.05) and contracted unevenly with MAR (p < 0.05). In anterior region of OP300, all materials magnified without MAR, (p ≥ 0.05) and had shape distortion with MAR (p < 0.05). In posterior region, only Am showed magnification without MAR (p ≥ 0.05), while all materials presented shape distortion with MAR (p < 0.05).
Conclusion:
Dimensional changes of high-density materials in CBCT can be either a magnification, a contraction or a distortion; the last condition is the most prevalent. Furthermore, changes differ considering material, anatomical region and MAR condition.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Three-Dimensional Microscopy in Microbiology
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...