Related Experiment Video
Updated: Nov 2, 2025

High Resolution Physical Characterization of Single Metallic Nanoparticles
Published on: June 28, 2019
Polymeric membrane-modified voltammetric sensors for lipophilic analytes with nanomolar detection limit: Key
Marcin Guzinski1, Ernő Lindner2, Bradford Pendley2
1Vanderbilt Eye Institute, Vanderbilt University Medical Center, Nashville TN, 37232, USA.
Abstract:
Thin plasticized PVC membrane-coated glassy carbon working electrodes have been used for the voltammetric measurement of highly lipophilic, electroactive drugs. Compared to conventional working electrodes, these membrane-coated electrodes exhibit remarkable detection limit and selectivity and are less prone to electrode fouling. The unique performance characteristics of these sensors are related to the large partition coefficient of the analyte in the membrane coating where it is oxidized in a non-aqueous membrane phase. To analyze the influence of the key parameters of the response of membrane-coated sensors, we derived theoretical expressions on the voltammetric response of the sensors. In our analysis we considered 1) the partition coefficient (Pmw) of the analyte between the aqueous sample and the organic membrane, 2) the membrane volume to sample volume ratio (Vm/Vw), and 3) the binding constant of constituents in the sample that bind the analyte (K). The results of our theoretical analysis have been tested through voltammetric measurement of highly lipophilic analytes with logPow values (logarithm of the partition coefficient between octanol and water) ranging between 0.3 and 7.5. By understanding of the influence of the sensor design parameters on the overall sensor response, these parameters can be tuned for optimized response slope, detection limit, etc., for solving specific analytical tasks.
More Related Videos
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
09:12Selection of Transporter-Targeted Inhibitory Nanobodies by Solid-Supported-Membrane SSM-Based Electrophysiology
Published on: May 3, 2021
Related Concept Videos
Potentiometry: Membrane Electrodes
High-Performance Liquid Chromatography: Types of Detectors
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Linear-Scan (E vs Time)