rMSIannotation: A peak annotation tool for mass spectrometry imaging based on the analysis of isotopic intensity
Lluc Sementé1, Gerard Baquer1, María García-Altares2
1University Rovira I Virgili, Department of Electronic Engineering, Tarragona, Spain.
Abstract:
Mass spectrometry imaging (MSI) consist of spatially located spectra with thousands of peaks. Only a fraction of these peaks corresponds to unique monoisotopic peaks, as mass spectra include isotopes, adducts and fragments of compounds. Current peak annotation solutions depend on matching MS features to compounds libraries. We present rMSIannotation, a peak annotation algorithm to annotate carbon isotopes and adducts in metabolomics and lipidomics imaging mass spectrometry datasets without using supporting libraries. rMSIannotation measures and evaluates the intensity ratio between carbon isotopic peaks and models their distribution across the m/z axis of the compounds in the Human Metabolome Database. Monoisotopic peak selection is based on the isotopic likelihood score (ILS) made of three components: image morphology correlation, validation of isotopic intensity ratios, and peak centroid mass deviation. rMSIannotation proposes pairs of peaks that can be adducts based on three scores: isotopic pattern coherence, image correlation and mass error. We validated rMSIannotation with three MALDI-MSI datasets which were manually annotated by experts, and compared the annotations obtained with rMSIannotation and with the METASPACE annotation platform. rMSIannotation replicated more than 90% of the manual annotation reported in FT-ICR datasets and expanded the list of annotated compounds with additional monoisotopic peaks and neutral masses. Finally, we evaluated isotopic peak annotation as a data reduction method for MSI by comparing the results of PCA and k-means segmentation before and after removing non-monoisotopic peaks. The results show that monoisotopic peaks retain most of the biologic variance in the dataset.
Related Concept Videos
Mass Spectrometry: Isotope Effect
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrum: Interpretation
To...
Mass Spectrum
Mass Spectrometry: Overview