A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Implantable cardioverter-defibrillator programming after first occurrence of ventricular tachycardia in the
Mehmet K Aktas1, Amanda L Bennett1, Arwa Younis1
1Clinical Cardiovascular Research Center, University of Rochester Medical Center, Rochester, New York.
Background:
Implantable cardioverter-defibrillator (ICD) programming to novel settings can reduce the risk of inappropriate therapies.
Objective:
The purpose of this study was to evaluate the impact of novel ICD programming after the first occurrence of ventricular tachycardia (VT).
Methods:
In MADIT-RIT (Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy) patients who experienced a first occurrence of VT, the risk of subsequent inappropriate and appropriate ICD therapies and adverse cardiovascular events by ICD programming to Arm A (conventional: VT ≥170 bpm), Arm B (high rate: VT ≥200 bpm), or Arm C (duration delay: ≥60-second delay before therapy ≥170 bpm) was determined.
Results:
Among 205 patients, ICD programming changes were made in 30 patients (15%) after they experienced a VT episode; 117 patients (57%) were programmed to Arm A settings and 88 patients (43%) to Arm B/C settings. At 15-month follow-up, the cumulative probability of inappropriate ICD therapy was significantly lower in Arm B/C compared to Arm A (9% vs 20%; log-rank P = .029 for overall difference). The rate of appropriate ICD therapy also was significantly lower in Arm B/C compared to Arm A (32% vs 64%; log-rank P = .001 for overall difference). Multivariate analysis showed that patients programmed to Arm B/C after the occurrence of VT had a 71% reduction (P = .02) in the risk of inappropriate ICD therapies and a 43% reduction (P = .02) in the risk of appropriate ICD therapies compared to Arm A.
Conclusion:
The benefit of high-rate cutoff or duration delay settings in patients with an ICD is maintained after the first occurrence of VT.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
05:12Transesophageal Atrial Burst Pacing for Atrial Fibrillation Induction in Rats
Published on: February 14, 2022
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Cardiopulmonary Resuscitation III: AED Use
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias VI: Management of Dysrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiomyopathy II: Dilated Cardiomyopathy