A J Wilson1, B J Cuddigan, A P Wyatt
1Brook General Hospital, London.
Abstract:
Intraoperative autotransfusion of whole blood was performed using the Solcotrans device in 45 patients undergoing major vascular surgery or other procedures in which there was a clean operative field. Overall, 60% of the blood shed during these operations was reinfused. Approximately 50% of patients avoided the potential complications of homologous transfusion. There were no complications attributable to the use of this device although in a sample of 13 patients, 30% of the erythrocytes were haemolysed and there were other minor haematological abnormalities. In conclusion this device provides a simple method of autotransfusing 2 or 3 litres of blood aspirated from an uncontaminated operative field.