Related Experiment Video
Updated: Nov 2, 2025

A Protocol for Comprehensive Assessment of Bulbar Dysfunction in Amyotrophic Lateral Sclerosis ALS
Published on: February 21, 2011
Differences and Reliability of Linear and Nonlinear Acoustic Measures as a Function of Vocal Intensity in Individuals
Vanessa de Oliveira Florencio1, Anna Alice Almeida2, Patrícia Balata2
1Graduate Program in Speech, Language and Hearing Sciences, Universidade Federal da Paraíba (UFPB), João Pessoa, Paraíba, Brazil.
Purpose:
Linear acoustic indices are significantly influenced by speaking voice intensity. The main aim of this work was to compare acoustic measures based on linear and nonlinear models in different speaking voice intensity levels and to analyze the reliability of those measures in different intensity levels in subjects with voice disorders.
Methods:
435 samples from subjects (314 women, 121 men with a mean age of 41.07 ± 13.73) diagnosed with various voice disorders were used. In total, 17 acoustic measures were derived from the vowel /ɛ/ sustained at three intensity levels (soft, comfortable, and loud). Five were linear (standard deviation of the fundamental frequency (f0), jitter, shimmer, harmonics-to-noise ratio (HNR) and smoothed cepstral peak prominence (CPPS)), and twelve were nonlinear measures, namely correlation dimension (D2), correlation entropy (H2), first minimum of the mutual information function (FMMI), relative entropy (ENTR-R), largest Lyapunov exponent (Lyap), determinism (DET), transitivity, mean diagonal line length (Lmed), Shannon entropy (ENTR-S), mean length of vertical structures, also known as trapping time (TT), laminarity (LAM) and recurrence period density entropy (RPDE). Differences between speaking voice intensity levels were assessed by Friedman's test and Nemenyi as posthoc test. Intraclass correlation coefficient was used to investigate if each acoustic measure remains in agreement (reliability) between different voice intensity levels.
Results:
There were significant differences in all acoustic measures about vocal intensity level (P < 0.001). Intraclass correlation coefficient was very good for HNR (>0.61) and good for Lyap, DET, ENTR-S, Lmed, RPDE, and TT (0.41-0.60).
Conclusions:
All acoustic measures varied as a function of vocal intensity in voice disordered adults, while this relation was different for linear and nonlinear measures. Only the measures HNR, Lyap, DET, ENTR-S, Lmed, RPDE and TT had an acceptable reliability between different voice intensity levels. Therefore, patient`s voice SPL should be controlled or indicated during acoustic vocal assessment.
More Related Videos
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Sound Intensity
Larynx
Anatomy of the Larynx
The larynx consists of various components, including cartilage, muscles, and vocal cords. Its structure includes three large unpaired cartilages—the thyroid, cricoid, and epiglottis—and three smaller paired cartilages—the arytenoids,...
Applications of Logarithms
Perception of Sound Waves
The pitch of a sound depends on the frequency and the pressure amplitude of the source. Two sounds of the same...
Perceiving Loudness, Pitch, and Location
Place theory, or place coding, suggests that different pitches are heard because various sound waves activate specific locations along the cochlea's basilar membrane. The brain determines the pitch of a sound by...

