Miniaturized TOC analyzer using dielectric barrier discharge for catalytic oxidation vapor generation and point
Kai Li1, Hanjiao Chen1, Zhiming Chen2
1Analytical & Testing Center, Sichuan University, Chengdu, Sichuan, 610064, China.
Abstract:
Total organic carbon (TOC) is an important parameter describing organic pollution degree of waters. Due to the increasing need of field analysis and drawbacks of conventional TOC analytical instruments, miniaturized TOC analyzers are still demanding. In this work, a dielectric barrier discharge (DBD) microplasma was utilized for catalytic oxidation vapor generation (COVG) of organic compounds into CO2, and a point discharge (PD) microplasma was employed to excite the carbon atomic emission spectra for quantification. Sample solution with phosphoric acid and persulfate solution was injected into the DBD-COVG reactor by a syringe to convert organic compounds into CO2 efficiently and quickly, which was subsequently transported into the point discharge optical emission spectrometer (PD-OES) for detecting carbon at 193.09 nm. Under optimal experimental conditions, high oxidation efficiencies for several organic compounds were achieved, i.e., 96.4%, 95.1% and 94.3% for 50 mg L-1 potassium hydrogen phthalate (KHP), sodium laurylsulfonate and phenol, respectively. A limit of detection (LOD) of 0.02 mg L-1 (as C) was obtained, with a precision of 3.9% (relative standard deviation, RSD) at 15 mg L-1 TOC standard (as C). The possible catalytic oxidation mechanism was proposed with the characteristic results of electron paramagnetic resonance (EPR). Its potential environmental application was demonstrated by successfully analyzing TOC in underground water, surface river water and surface sedimentary water samples from oil fields, with analytical results agreed well with those obtained by the commercial high-temperature combustion coupled nondispersive infrared absorption (HTC-NDIR) technique.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
08:59Measuring Sub-23 Nanometer Real Driving Particle Number Emissions Using the Portable DownToTen Sampling System
Published on: May 22, 2020
Related Concept Videos
Atomic Emission Spectroscopy: Instrumentation
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...