Pulseless Electrical Activity as the Initial Cardiac Arrest Rhythm: Importance of Preexisting Left Ventricular
Daniel I Ambinder1, Kaustubha D Patil1, Hikmet Kadioglu1
1Division of Cardiology Department of Medicine Johns Hopkins University Baltimore MD.
Abstract:
Background Pulseless electrical activity (PEA) is a common initial rhythm in cardiac arrest. A substantial number of PEA arrests are caused by coronary ischemia in the setting of acute coronary occlusion, but the underlying mechanism is not well understood. We hypothesized that the initial rhythm in patients with acute coronary occlusion is more likely to be PEA than ventricular fibrillation in those with prearrest severe left ventricular dysfunction. Methods and Results We studied the initial cardiac arrest rhythm induced by acute left anterior descending coronary occlusion in swine without and with preexisting severe left ventricular dysfunction induced by prior infarcts in non-left anterior descending coronary territories. Balloon occlusion resulted in ventricular fibrillation in 18 of 34 naïve animals, occurring 23.5±9.0 minutes following occlusion, and PEA in 1 animal. However, all 18 animals with severe prearrest left ventricular dysfunction (ejection fraction 15±5%) developed PEA 1.7±1.1 minutes after occlusion. Conclusions Acute coronary ischemia in the setting of severe left ventricular dysfunction produces PEA because of acute pump failure, which occurs almost immediately after coronary occlusion. After the onset of coronary ischemia, PEA occurred significantly earlier than ventricular fibrillation (<2 minutes versus 20 minutes). These findings support the notion that patients with baseline left ventricular dysfunction and suspected coronary disease who develop PEA should be evaluated for acute coronary occlusion.
More Related Videos
08:28Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
Published on: April 5, 2011
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiopulmonary Resuscitation IV: Pharmacological Management
Mechanism of Cardiac Arrhythmias
