Related Experiment Video
Updated: Nov 2, 2025

Preparation of Gynura bicolor DC samples for High-Resolution Tandem Mass Spectrometry
Published on: February 2, 2024
Simultaneous Quantification of 14 Compounds in Achillea millefolium by GC-MS Analysis and Near-Infrared Spectroscopy
Lan-Ping Guo1, Jian Yang1, Li Zhou1
1National Resource Center for Chinese Materia Medica, China Academy of Chinese Medical Sciences, State Key Laboratory Breeding Base of Dao-di Herbs, Beijng 100700, China.
Abstract:
The proposed work is focused on the simultaneous quantification of 14 compounds in the medicinal plant Achillea millefolium based on Near-Infrared Spectroscopy (NIR). The regression model of single-compound models (SCMs) and multicompound model (MCM) were created by partial least-squares regression (PLSR). Also, these models were calibrated by gas chromatographic mass spectroscopy (GC-MS). The results showed that the averaged standard errors of prediction (SEP) for the SCMs and MCM were 0.49 and 0.62, respectively, and most of the 14 compounds were significantly correlated. 43 correlations were significant at the 0.01 level (47.25% of the total), and 11 correlations were significant at the 0.05 level (12.09% of the total). The first three principal components (PCs) of principal component analysis (PCA) can explain >78% of the total variance. According to the component matrix and the communality table, octadecanoic acid has the largest influence on PC 1 (extraction squared = 46.72%), whose extraction was 0.932. The communality of neophytadiene, Z,Z,Z-9,12,15-octadecatrienoic acid, and oleic acid was also found to be large, whose extractions were 0.955, 0.937, and 0.859, respectively. These results indicate that if one compound shows a linear relationship with the NIR absorbance signal (SCM) also, an MCM can be created due to the close interrelations of these compounds. In this context, the present work highlights a suitable sample preparation technique to perform NIR analysis of raw plant material to benefit from robust and precise calibrations. To sum up, this NIR spectroscopic approach offers a precise, rapid, and cost-effective high-throughput analytical technique to simultaneously and noninvasively perform quantitative analysis of raw plant materials.
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....