Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Dysrhythmias IV: Characteristics of Bradyarrhythmias01:18

Dysrhythmias IV: Characteristics of Bradyarrhythmias

261
Bradyarrhythmias are cardiac rhythm disorders characterized by a slower-than-normal heart rate, typically defined as fewer than 60 beats per minute. Some of which are discussed here:Sinus BradycardiaSinus bradycardia presents a heart rate lower than 60 beats per minute, with a regular rhythm originating from the SA node. The ECG typically shows normal P waves preceding each QRS complex, a normal PR interval (0.12 to 0.20 seconds), and a normal QRS duration (0.06 to 0.10 seconds).First-Degree AV...
261
Conduction System of the Heart01:19

Conduction System of the Heart

11.2K
Autorhythmicity is a term that refers to the heart's inherent ability to generate electrical signals and instigate muscle contractions. This self-regulating conduction system within the heart consists of two key components: the pacemaker cells and specialized conducting cells.
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
11.2K
Conduction System of the Heart01:20

Conduction System of the Heart

2.3K
The cardiac conduction system produces and transmits electrical impulses that prompt myocardial contraction, ensuring efficient heart function. This intricate system ensures that the heart beats in a coordinated and efficient manner, beginning with the atria and then the ventricles. The conduction system optimizes cardiac output by maintaining this precise sequence, which is crucial for adequate blood circulation.
This system relies on the unique properties of nodal and Purkinje cells:...
2.3K
Cardiac Catheterization III: Left Heart Catheterization01:24

Cardiac Catheterization III: Left Heart Catheterization

301
Left heart catheterization is an invasive diagnostic procedure used to evaluate the function and structure of the left side of the heart. It is generally performed to diagnose and treat cardiovascular conditions such as valve abnormalities, coronary artery disease, and congenital heart defects.Diagnostic and therapeutic purposesLeft heart catheterization serves various diagnostic and therapeutic purposes, including:Assessing coronary artery bypass grafts.Evaluating coronary artery disease in...
301
The Cardiac Cycle01:13

The Cardiac Cycle

92.7K
The heart beats rhythmically in a sequence called the cardiac cycle—a rapid coordination of contraction (systole) and relaxation (diastole).
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
92.7K
Electrophysiology of Normal Cardiac Rhythm01:19

Electrophysiology of Normal Cardiac Rhythm

7.8K
The normal cardiac rhythm is a synchronized electrical activity that facilitates the regular and coordinated contraction of the heart muscle. This process is essential for efficient blood circulation throughout the body. The fundamental elements involved in establishing and maintaining this rhythm include the unique electrical properties of cardiac muscle cells, the sinoatrial (SA) node's pacemaker function, the specialized conducting system, and the ionic mechanisms underlying each phase...
7.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Optimal pace timing for left bundle branch area pacing with or without an additional LV lead: results from the CSPOT study.

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology·2026
Same author

Left Bundle Branch Area Pacing: Does Lead Position Matter?

JACC. Clinical electrophysiology·2026
Same author

Radiofrequency current-facilitated implantation of left bundle branch pacing lead for cardiac resynchronization therapy.

Heart rhythm·2026
Same author

First positronium lifetime imaging using <sup>52</sup>Mn and <sup>55</sup>Co with a plastic-scintillator-based PET scanner.

Scientific reports·2026
Same author

Monte Carlo-based scatter correction for the plastic-based modular PET scanner J-PET.

Physics in medicine and biology·2026
Same author

First ex-vivo positronium imaging of tissues with modular J-PET scanner using <sup>44</sup>Sc radionuclide.

Zeitschrift fur medizinische Physik·2026

Related Experiment Video

Updated: Nov 2, 2025

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
12:45

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing

Published on: December 11, 2017

10.6K

Reaching the left bundle branch pacing area within 36 heartbeats

Marek Jastrzębski1, Paweł Moskal2

  • 11st Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University Medical College, Kraków, Poland. mcjastrz@cyf-kr.edu.pl.

Kardiologia Polska
|June 14, 2021
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
09:52

Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts

Published on: November 7, 2019

13.3K
Testing the Efficacy of Pharmacological Agents in a Pericardial Target Delivery Model in the Swine
10:05

Testing the Efficacy of Pharmacological Agents in a Pericardial Target Delivery Model in the Swine

Published on: July 7, 2016

8.5K

Related Experiment Videos

Last Updated: Nov 2, 2025

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
12:45

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing

Published on: December 11, 2017

10.6K
Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
09:52

Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts

Published on: November 7, 2019

13.3K
Testing the Efficacy of Pharmacological Agents in a Pericardial Target Delivery Model in the Swine
10:05

Testing the Efficacy of Pharmacological Agents in a Pericardial Target Delivery Model in the Swine

Published on: July 7, 2016

8.5K