Recording of electrocochleography from the facial nerve canal in mice
Related Experiment Video
Updated: Nov 2, 2025

Combined Recording of Mechanically Stimulated Afferent Output and Nerve Terminal Labelling in Mouse Hair Follicle Lanceolate Endings
Published on: May 7, 2016
Wenjuan Li1, Dong Li2, Nina Chen2
1Department of Otolaryngology Head and Neck Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing, China; Department of Otolaryngology, Children's Hospital of Shanxi, Women health of Shanxi, Taiyuan, China.
Background:
The ever-expanding arsenal of genetically modified mice has created experimental models for studying various mechanisms of deafness. Electrocochleography (ECochG) is a recording technique of cochlear potentials evoked by sound stimulation, which was widely used to evaluate the cochlear hearing function. However, there is currently a lack of information on long-term recording technology of ECochG in mice.
New Method:
We describe in detail the surgical procedure of implanting electrode into the facial nerve canal in C57BL/6J mice for ECochG recording. The results of ECochG recorded by electrode in the facial nerve canal were compared with ECochG guided by electrode on the round window niche.
Results:
The surgical method of inserting the electrode into the facial nerve canal is relatively simple and can be completed within 15 min. The electrode inserted into the elongated facial nerve canal is stable and close to the auditory nerve trunk, so it is conducive to long-term auditory function monitoring. Hence, the ECochG guided by the electrode from the facial nerve canal can maintain a stable response for more than two weeks. In contrast, the ECochG guided by the electrode in the round window niche can only be maintained for a maximum of 20 min.
Comparison With Existing Methods:
In mice, existing recording techniques of ECochG from round window niche is limited by conductive hearing loss due to middle ear effusion or surgical damage.
Conclusions:
ECochG recording from the facial nerve canal is suitable for long-term recording in mice. This electrode approach provides a repeatable and reliable measurement of ECochG.
More Related Videos
05:26Author Spotlight: Low-Cost Electroencephalographic Recording System Combined with a Millimeter-Sized Coil to Transcranially Stimulate the Mouse Brain In Vivo
Published on: May 26, 2023
07:52Multiscale Investigations of Cortical Processing by Integrating Laminar Polytrodes and Optogenetics with Micro Electrocorticography in Rodents
Published on: May 23, 2025