Related Experiment Video
Updated: Nov 2, 2025

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Impact of a commercially available DOAC absorbent on two integrated procedures for lupus anticoagulant detection
Armando Tripodi1, Erica Scalambrino2, Veena Chantarangkul1
1IRCCS Ca' Granda Ospedale Maggiore Foundation, Angelo Bianchi Bonomi Hemophilia and Thrombosis Center, Milano, Italy; Fondazione Luigi Villa, Milano, Italy.
Background:
Lupus anticoagulant (LA)-detection in anticoagulated patients is an unmet need, which becomes even more cogent with the introduction of direct oral anticoagulants (DOAC) that may lead to false-positive results.
Aims:
We aimed to investigate the effect of a commercially available DOAC absorbent on residual drug concentrations, and on integrated procedures for LA-detection.
Methods:
Blood from patients treated for atrial fibrillation with either dabigatran (n = 39), rivaroxaban (n = 55), apixaban (n = 47) or edoxaban (n = 47) were collected at peak and trough, and centralized for testing with two LA integrated procedures [i.e., the silica clotting time (SCT) and dilute Russel viper venom (dRVVT)] before and after DOAC absorbent exposure.
Results:
The commercially available DOAC absorbent investigated in this study proved effective in reducing the concentrations of all the investigated DOAC, although small residual drug was detected after absorption, especially in patients on edoxaban. Results mimicking LA were observed in patients on DOAC before absorbent exposure, especially for rivaroxaban when testing was performed with dRVVT (88% rate at peak and 20% at trough) and much less with SCT (12% at peak and 8% at trough). The correspondent rate of results mimicking LA in patients on rivaroxaban after exposure was reduced [dRVVT (peak 8%, trough 4%); SCT (peak and trough 8%)], but not abolished.
Conclusions:
Overall, in vitro DOAC absorbance by active charcoal compounds is a useful laboratory tool for LA-detection in patients on DOAC. Caution should however be exerted when used in daily practice.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...