Related Experiment Video
Updated: Nov 2, 2025

A Microfluidic Model of Biomimetically Breathing Pulmonary Acinar Airways
Published on: May 9, 2016
Measurements of exhaled airflow velocity through human coughs using particle image velocimetry
Mengtao Han1, Ryozo Ooka2, Hideki Kikumoto2
1School of Architecture and Urban Planning, Huazhong University of Science and Technology, Wuhan, China.
Abstract:
The sudden outbreak of coronavirus (COVID-19) has infected over 100 million people and led to over two million deaths (data in January 2021), posing a significant threat to global human health. As a potential carrier of the novel coronavirus, the exhaled airflow of infected individuals through coughs is significant in virus transmission. The research of detailed airflow characteristics and velocity distributions is insufficient because most previous studies utilize particle image velocimetry (PIV) with low frequency. This study measured the airflow velocity of human coughs in a chamber using PIV with high frequency (interval: 1/2986 s) to provide a detailed validation database for droplet propagation CFD simulation. Sixty cough cases for ten young healthy nonsmoking volunteers (five males and five females) were analyzed. Ensemble-average operations were conducted to eliminate individual variations. Vertical and horizontal velocity distributions were measured around the mouth area. Overall cough characteristics such as cough duration time (CDT), peak velocity time (PVT), maximum velocities, and cough spread angle were obtained. The CDT of the cough airflow was 520-560 m s, while PVT was 20 m s. The male/female averaged maximum velocities were 15.2/13.1 m/s. The average vertical/horizontal cough spread angle was 15.3°/13.3° for males and 15.6°/14.2° for females. In addition, the spatial and temporal distributions of ensemble-averaged velocity profiles were obtained in the vertical and horizontal directions. The experimental data can provide a detailed validation database the basis for further study on the influence of cough airflow on virus transmission using computational fluid dynamic simulations.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Respiratory Volumes and Capacities
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity...

