Nickel Hypersensitivity to Atrial Septal Occluders: Smoke Without Fire?
Anastasios Apostolos1, Maria Drakopoulou1, Stamatios Gregoriou2
1First Department of Cardiology, Medical School, National and Kapodistrian University of Athens, Hippokration General Hospital, Athens, Greece.
Nickel allergy after device closure for atrial septal defects (ASDs) and patent foramen ovale (PFO) is rare but causes symptoms. More research is needed to understand and diagnose this "device syndrome."
Area of Science:
- Cardiology
- Allergy and Immunology
- Biomaterials Science
Background:
- Nickel is a prevalent contact allergen, frequently used in medical devices for cardiac defect closure.
- Nickel hypersensitivity following atrial septal defect (ASD) and patent foramen ovale (PFO) device occlusion is infrequently reported compared to typical sensitization.
- The existence and incidence of this
- device syndrome,
Purpose of the Study:
- To explore the clinical entity of nickel hypersensitivity developing after percutaneous PFO/ASD device closure.
- To review the associated symptoms, diagnostic challenges, and current management strategies.
- To highlight the need for further research into the pathophysiology and diagnostic methods for device-related nickel hypersensitivity.
Main Methods:
- Literature review of reported cases of nickel hypersensitivity after PFO/ASD device closure.
- Analysis of clinical manifestations, diagnostic approaches (including skin patch tests), and treatment outcomes.
- Discussion of the diagnostic challenges and the empirical nature of current management.
Main Results:
- Nickel hypersensitivity after PFO/ASD occlusion is a rare but recognized complication.
- Associated symptoms can be diverse, including chest pain, migraines, palpitations, and dyspnea.
- Diagnosis is often by exclusion, lacking specific criteria, and management is empirical, ranging from medication to device explantation.
Conclusions:
- Endocardiac device-related nickel hypersensitivity, or "device syndrome," warrants further investigation.
- There is a critical need for research to elucidate the underlying mechanisms.
- Development of reliable prognostic tests and preventative strategies for high-risk patients is essential.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Antiarrhythmic Drugs: Class II Agents as β-Adrenergic Blockers
Antiarrhythmic Drugs: Class I Agents as Sodium Channel Blockers
Class 1A Antiarrhythmic Drugs: These drugs work by moderately blocking sodium channels,...
Allergic Drug Reactions
Aortic Regurgitation III: Medical Management
Cardiac Catheterization IV: Nursing Management
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...