Related Experiment Video
Updated: Nov 2, 2025

Photoselective Vaporesection of the Prostate via an End-firing Lithium Triborate Crystal Laser
Published on: May 9, 2018
Does the power of the laser devices matter for a successful HoLEP procedure? A prospective comparative study
Zafer Tokatli1, Mehmet Ferhat2, Muhammed Arif Ibis3
1Department of Urology, Medicana International Ankara Hospital, Ankara, Turkey.
Background:
The objectives of this prospective study were to evaluate the efficiency, safety and applicability of medium-power (MP) holmium laser devices in the endoscopic enucleation of the enlarged prostate (HoLEP) compared with high-power (HP) laser devices.
Methods:
From October 2019 to July 2020, a total of 120 consecutive patients planned for HoLEP were divided randomly into two groups formed in terms of the power of the device used. While patients in group 1 were treated with a MP device (50 W) at 39.6 W (2.2 J/18 Hz), patients in group 2 were treated with HP (100 W) device at 42 W (1.2 J/35 Hz). Preoperative patient characteristics, perioperative measures and 3-month functional outcomes were evaluated in both groups with an emphasis on enucleation efficiency (EE) and haemoglobin decrease in a comparative manner.
Results:
All patients underwent successful HoLEP surgery with no severe perioperative and postoperative complications. No statistically significant differences were observed in terms of preoperative patient characteristics and perioperative measures in the two groups. The median EE values in groups 1 and 2 were 1.15 (interquartile range [IQR]: 0.33-2.2) and 1.11 (IQR: 0.4-2.8), respectively (P = .775). Haemoglobin decrease values in groups 1 and 2 were 1.3 (IQR: 0.1-4) and 1.4 (IQR: 0.4-3.1), respectively (P = .736). There was no difference in terms of either catheterisation time or hospital stay in the groups. In the model created to predict haemoglobin decrease, only biopsy was detected to be the independent predictive factor among the data from laser device, biopsy and antithrombotic use. Functional outcomes markedly improved in all patients without any statistically significant difference between the groups in the 3-month follow-up.
Conclusion:
Our comparative study indicated that HoLEP can be performed safely and effectively with MP laser devices without any technical difficulties and with comparable results achieved in HP laser devices.

