Ture Lange Nielsen1,2, Katrine Pilely1, Kit P Lund1
1Laboratory of Molecular Medicine, Department of Clinical Immunology, University of Copenhagen, Copenhagen, Denmark.
Introduction:
This study aimed to investigate changes in complement system-related molecules in patients undergoing hemodialysis.
Methods:
Patients >18 years of age on maintenance hemodialysis were included. Using enzyme-linked immunosorbent assays (ELISA) methods complement related molecules ficolin-1, ficolin-2, ficolin-3 mannose-binding lectin, long pentraxin 3, complement activation products C3c, and complement activation potentials were measured before and after a single hemodialysis treatment. All patients were dialyzed with synthetic high flux filters >1.6 m2 , respectively, Polyamix and Polysulfone, and the Kt/V was maintained >1.3.
Findings:
Three hundred and four patients were included. There was a modest decrease in plasma level of ficolin-1 (p < 0.001). Ficolin-2 was virtually depleted with median 3.9 (interquartile range [IQR]: 2.6-6.1, range 0.3-13.5) μg/ml before dialysis to median 0.0 (IQR: 0.0-0.5, range 0.0-5.5) μg/ml after dialysis (p < 0.001). No significant difference before and after hemodialysis was seen for mannose-binding lectin and long pentraxin 3 (p > 0.05). In a random subgroup of 160 patients ficolin-2-binding, ficolin-3-mediated lectin pathway capacity and classical pathway capacity were significantly decreased due to hemodialysis. The complement capacity of the alternative pathway was increased after hemodialysis (p = 0.0101), while mannose-binding lectin-mediated lectin pathway capacity was unaltered (p = 0.79). There was an increase in the complement activation product C3c (p < 0.0001), while the concentration of total C4 and C3 did not change (p > 0.158). Multivariate Cox proportional hazard analyses showed an increased risk for all-cause mortality with increasing ficolin-2 (p = 0.002) after hemodialysis.
Discussion:
Plasma ficolin-2 was virtually depleted from the circulation after hemodialysis. However, elevated plasma ficolin-2 levels after hemodialysis was independently associated with increased mortality.
Related Concept Videos
Hemodialysis II: Procedure and Complications
Hemodialysis I: Introduction
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Dialysis
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Renal Corpuscle
Glomerulus: Structure and Function
The glomerulus is a tiny, intricate network of capillaries located at the beginning of the nephron. It's enveloped by the Bowman's capsule and receives its blood supply from an afferent arteriole, which divides into numerous...