Related Experiment Video
Updated: Nov 2, 2025

Diffusion Tensor Magnetic Resonance Imaging in Chronic Spinal Cord Compression
Published on: May 7, 2019
Spinal nerve signal intensity on Dixon T2-weighted water-only sequence: an important outcome predictor after lumbar
Yong Hee Kim1, Hyo Jin Kim1, Jiwoon Seo1
1Department of Radiology, Seoul Metropolitan Government - Seoul National University Boramae Medical Center, Seoul National University College of Medicine, 20, Boramae-ro 5-gil, Dongjak-gu, Seoul, 07061, Republic of Korea.
Objectives:
To evaluate the role of Dixon T2-weighted water-fat separation technique in predicting the outcome of lumbar transforaminal epidural injections (TFESIs).
Methods:
Patients who underwent TFESI of a single spinal nerve within 3 months after magnetic resonance imaging (MRI) exam between August 2018 and April 2020 were identified. The patients were classified into positive or negative outcome groups based on the response to the TFESI procedure. Two musculoskeletal radiologists measured the signal intensity of the injected side spinal nerves, contralateral side spinal nerves, and subcutaneous fat on axial Dixon T2-weighted water-only images, and the diameter of spinal nerve on axial Dixon T2-weighted in-phase images of the pre-procedural MRI. The measured values of the injected side spinal nerves were compared between the two groups and with the contralateral side spinal nerve.
Results:
A total of 94 patients were included, 76 in the positive outcome group and 18 in the negative outcome group. The mean signal intensity and the nerve-to-fat signal ratio of the injected side spinal nerve were significantly higher in the positive outcome group than in the negative outcome group (793.78 vs. 679.19, p = 0.016; 4.21 vs. 3.28, p = 0.003). In the positive outcome group, the diameter of the spinal nerve was significantly higher on the injected side than on the contralateral side (6.91 mm vs. 6.37 mm, p = 0.016).
Conclusions:
The mean signal intensity and the nerve-to-fat signal ratio of the spinal nerve on axial Dixon T2-weighted water-only images can help predict patient response to the TFESI.
Key Points:
• Applying the Dixon technique to lumbar spine MRI can help predict patient response to the TFESI procedure. • An increased nerve-to-fat signal ratio and mean spinal nerve signal intensity on axial Dixon T2-weighted water-only images predicted favorable TFESI outcomes.
More Related Videos
03:14Author Spotlight: Enhancing Success of Ultrasound-Guided Neuraxial Anesthesia in Cases with Difficult Anatomy
Published on: January 31, 2025
05:24In Vivo SiRNA Transfection and Gene Knockdown in Spinal Cord via Rapid Noninvasive Lumbar Intrathecal Injections in Mice
Published on: March 22, 2014
Related Concept Videos
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...