Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

757
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
757
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

1.2K
Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
1.2K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

936
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
936

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Dual-Functional Fluorinated Additive in Gel Polymer Electrolyte for High-Energy-Density Anode-Free Lithium Batteries With Enhanced Thermal Stability.

Advanced materials (Deerfield Beach, Fla.)·2026
Same author

Achieving Fermi-Level Depinning and Ideal Metal Contact in <i>β</i>-Ga<sub>2</sub>O<sub>3</sub> Devices via MXene Integration.

Nano letters·2026
Same author

Navigating polymorph generation and distilled-potential development via entropy-symmetry landscapes for metal plasticity mechanisms.

Nature communications·2026
Same author

Volcano Plot of Transition Metal Disulfides in Aqueous Zinc Ion Storage.

Nano letters·2026
Same author

Atomic Insights of Irradiation-Induced Thermal Conductivity Degradation in β-Ga<sub>2</sub>O<sub>3</sub>.

The journal of physical chemistry letters·2026
Same author

Energy Level Engineering of PbS Quantum Dots via Aluminum Surface Modification for High-Performance Infrared Photodetectors.

Nano letters·2025

Related Experiment Video

Updated: Nov 1, 2025

Aerosol-assisted Chemical Vapor Deposition of Metal Oxide Structures: Zinc Oxide Rods
06:39

Aerosol-assisted Chemical Vapor Deposition of Metal Oxide Structures: Zinc Oxide Rods

Published on: September 14, 2017

13.3K

Two-Dimensional Gallium Oxide Monolayer for Gas-Sensing Application.

Junlei Zhao1, Xinran Huang1, Yiheng Yin2

  • 1Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen 518055, China.

The Journal of Physical Chemistry Letters
|June 17, 2021
PubMed
Summary

A novel two-dimensional Gallium oxide (Ga2O3) monolayer shows promise for gas sensing. Its unique structure enables selective detection of Nitrogen dioxide (NO) at room temperature with high sensitivity.

More Related Videos

A Standard and Reliable Method to Fabricate Two-Dimensional Nanoelectronics
07:12

A Standard and Reliable Method to Fabricate Two-Dimensional Nanoelectronics

Published on: August 28, 2018

9.9K
Synthesis and Characterization of High c-axis ZnO Thin Film by Plasma Enhanced Chemical Vapor Deposition System and its UV Photodetector Application
08:18

Synthesis and Characterization of High c-axis ZnO Thin Film by Plasma Enhanced Chemical Vapor Deposition System and its UV Photodetector Application

Published on: October 3, 2015

15.5K

Related Experiment Videos

Last Updated: Nov 1, 2025

Aerosol-assisted Chemical Vapor Deposition of Metal Oxide Structures: Zinc Oxide Rods
06:39

Aerosol-assisted Chemical Vapor Deposition of Metal Oxide Structures: Zinc Oxide Rods

Published on: September 14, 2017

13.3K
A Standard and Reliable Method to Fabricate Two-Dimensional Nanoelectronics
07:12

A Standard and Reliable Method to Fabricate Two-Dimensional Nanoelectronics

Published on: August 28, 2018

9.9K
Synthesis and Characterization of High c-axis ZnO Thin Film by Plasma Enhanced Chemical Vapor Deposition System and its UV Photodetector Application
08:18

Synthesis and Characterization of High c-axis ZnO Thin Film by Plasma Enhanced Chemical Vapor Deposition System and its UV Photodetector Application

Published on: October 3, 2015

15.5K

Area of Science:

  • Materials Science
  • Surface Science
  • Computational Chemistry

Background:

  • Two-dimensional (2D) materials offer unique properties for advanced applications.
  • Gallium oxide (Ga2O3) is a promising material for electronic and sensing devices.
  • Asymmetric structures in 2D materials can lead to enhanced functionality.

Purpose of the Study:

  • To investigate the adsorption behavior of various molecular gases on a 2D Ga2O3 monolayer.
  • To explore the potential of 2D Ga2O3 for gas sensing applications.
  • To understand the influence of surface orientation and strain on gas adsorption.

Main Methods:

  • First-principles calculations were employed to simulate gas adsorption.
  • Systematic investigation of adsorption energies and electronic structure changes.
  • Analysis of charge transport properties.

Main Results:

  • The 2D Ga2O3 monolayer exhibits excellent stability and strain tunability.
  • Asymmetric structure leads to distinct adsorption behaviors on top and bottom surfaces.
  • High sensitivity and tunable adsorption energy for Nitrogen dioxide (NO) detection at room temperature were predicted.

Conclusions:

  • The 2D Ga2O3 monolayer is a promising candidate for room-temperature gas sensors.
  • Surface orientation and strain engineering can optimize gas sensing performance.
  • Further research into this novel 2D material could lead to advanced sensor technologies.