Related Experiment Video
Updated: Nov 1, 2025

Ultrafast Time-resolved Near-IR Stimulated Raman Measurements of Functional π-conjugate Systems
Published on: February 10, 2020
Improvement of the coherent model function for S-branch Raman linewidth determination in oxygen
Abstract:
Determination of S-branch Raman linewidths of oxygen from picosecond time-domain pure rotational coherent anti-Stokes Raman spectroscopy (RCARS) measurements requires consideration of coherence beating. We present an optimization of the established model for fitting the coherence decay in oxygen, which leads to an improvement in Raman linewidth data quality, especially for the challenging small signal intensity and decay constant regime, enabling the application for low oxygen concentrations. Two modifications to the fitting procedure are discussed, which aim at reliably fitting the second coherence beat properly. These are evaluated statistically against simulated decay traces, and weighing the data by the inverse of the data magnitude gives the best agreement. The presented temperature dependent ${{\rm O}_2} {-} {{\rm O}_2}$ S-branch Raman linewidth from the modified model shows an improved data quality over the original model function for all studied temperatures. ${{\rm O}_2} {-} {{\rm N}_2}$ linewidths of oxygen in air for the temperature range from 295 K to 1900 K demonstrate applicability to small concentrations. Use of the determined RCARS ${{\rm O}_2} {-} {{\rm O}_2}$ S-branch linewidth instead of regularly used Q-branch derived linewidths leads to a lowering in evaluated RCARS temperature by about 21 K, thereby, a much better agreement with thermocouple measurements.
More Related Videos
Related Concept Videos
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
NMR Spectrometers: Resolution and Error Correction
Molecular Spectroscopy: Absorption and Emission

