Related Experiment Video
Updated: Nov 1, 2025

Transient Optical Clearing Using Absorbing Molecules for Ex Vivo and In Vivo Imaging
Published on: July 11, 2025
Double-path parallel convolutional neural network for removing speckle noise in different types of OCT images
Abstract:
Speckle noises widely exist in optical coherence tomography (OCT) images. We propose an improved double-path parallel convolutional neural network (called DPNet) to reduce speckles. We increase the network width to replace the network depth to extract deeper information from the original OCT images. In addition, we use dilated convolution and residual learning to increase the learning ability of our DPNet. We use 100 pairs of human retinal OCT images as the training dataset. Then we test the DPNet model for denoising speckles on four different types of OCT images, mainly including human retinal OCT images, skin OCT images, colon crypt OCT images, and quail embryo OCT images. We compare the DPNet model with the adaptive complex diffusion method, the curvelet shrinkage method, the shearlet-based total variation method, and the OCTNet method. We qualitatively and quantitatively evaluate these methods in terms of image smoothness, structural information protection, and edge clarity. Our experimental results prove the performance of the DPNet model, and it allows us to batch and quickly process different types of poor-quality OCT images without any parameter fine-tuning under a time-constrained situation.
Related Concept Videos
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Parallel Processing
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...

