Related Experiment Video
Updated: Nov 1, 2025

Lower Limb Biomechanical Analysis of Healthy Participants
Published on: April 15, 2020
Reporting errors in plain radiographs for lower limb trauma-a systematic review and meta-analysis
Thomas York1, Christopher Franklin2, Kate Reynolds2
1Guys and St Thomas' NHS Trust, St Thomas' Hospital, London, UK. thomas.york@nhs.net.
Introduction:
Plain radiographs are a globally ubiquitous means of investigation for injuries to the musculoskeletal system. Despite this, initial interpretation remains a challenge and inaccuracies give rise to adverse sequelae for patients and healthcare providers alike. This study sought to address the limited, existing meta-analytic research on the initial reporting of radiographs for skeletal trauma, with specific regard to diagnostic accuracy of the most commonly injured region of the appendicular skeleton, the lower limb.
Method:
A prospectively registered, systematic review and meta-analysis was performed using published research from the major clinical-science databases. Studies identified as appropriate for inclusion underwent methodological quality and risk of bias analysis. Meta-analysis was then performed to establish summary rates for specificity and sensitivity of diagnostic accuracy, including covariates by anatomical site, using HSROC and bivariate models.
Results:
A total of 3887 articles were screened, with 10 identified as suitable for analysis based on the eligibility criteria. Sensitivity and specificity across the studies were 93.5% and 89.7% respectively. Compared with other anatomical subdivisions, interpretation of ankle radiographs yielded the highest sensitivity and specificity, with values of 98.1% and 94.6% respectively, and a diagnostic odds ratio of 929.97.
Conclusion:
Interpretation of lower limb skeletal radiographs operates at a reasonably high degree of sensitivity and specificity. However, one in twenty true positives is missed on initial radiographic interpretation and safety netting systems need to be established to address this. Virtual fracture clinic reviews and teleradiology services in conjunction with novel technology will likely be crucial in these circumstances.
More Related Videos
08:20A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
Published on: March 24, 2019
09:34A Method to Estimate Cadaveric Femur Cortical Strains During Fracture Testing Using Digital Image Correlation
Published on: September 14, 2017