Related Experiment Video
Updated: Nov 1, 2025

Removal of Trace Elements by Cupric Oxide Nanoparticles from Uranium In Situ Recovery Bleed Water and Its Effect on Cell Viability
Published on: June 21, 2015
Performance of commercially available soil amendments for enhanced Cu attenuation in bioretention media
Matthew T Wilfong1, Ryan E Casey2, David R Ownby2
1Urban Environmental Biogeochemistry Laboratory (UEBL), Towson University, Towson, MD 21252, USA; Environmental Science and Technology Department, University of Maryland, College Park, MD 20740, USA.
Abstract:
Bioretention structures such as planter boxes, swales and rain gardens are being increasingly utilized in built landscapes as a strategy to attenuate both stormwater flows and contaminant loads. Copper (Cu) roofing materials contribute significantly higher mass loads of dissolved Cu per unit area than other surfaces such as parking lots and roadways. While a recent study demonstrated that conventional bioretention media can remove greater than 90% of Cu from copper roof runoff, the median Cu concentrations at the point of discharge from bioretention structures (66 μg L-1) still did not achieve Cu concentrations in stormwater discharges sought in some jurisdictions (for example, < 14 μg L-1). Consequently, commercially available soil amendments were assessed to improve bioretention Cu removal. The ability of biochar, greensand, and zeolite to improve Cu removal was evaluated in laboratory column studies. Additionally, the performance of zeolite as an underlayer amendment was evaluated in bioretention planter boxes treating stormwater from a picnic shelter with a partitioned copper roof. Cu was measured in the planter box influent and effluent. The field setup included 2 control planter boxes containing only standard bioretention media and 2 amended with the zeolite underlayer. Samples from ten storms were collected with flow-weighted composite sampling. Total Cu in composite samples of the influent waters ranged from 445 to 1683 μg L-1 and had a median concentration of 934 μg L-1. Total Cu in the effluent from the control planter boxes ranged from 10 to 64 μg L-1, with a mean of 29 μg L-1. Total Cu in effluent from the zeolite amended planter boxes ranged from 4 to 44 μg L-1 with a mean of 18 μg L-1. Attenuation in the control planter boxes ranged from 90 to 99% with a median of 93.4% by concentration and ranged from 95 to 99% with a median of 97.5% in the zeolite amended planter boxes.
More Related Videos
08:49Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
09:39Physical, Chemical and Biological Characterization of Six Biochars Produced for the Remediation of Contaminated Sites
Published on: November 28, 2014
Related Concept Videos
Bioremediation
Precipitation and Co-precipitation
Waterproofing and Anti-Bacterial Admixtures in Concrete
Waterproofing admixtures render concrete hydrophobic,...