Related Experiment Video
Updated: Nov 1, 2025

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
A framework for the development of targeted gas chromatography mass spectrometry (GC-MS) methods: Synthetic
Edward Sisco1, Amber Burns2, Arun S Moorthy1
1National Institute of Standards and Technology, Gaithersburg, MD, USA.
Abstract:
With the increased presence of novel psychoactive substances (NPSs) in casework, drug analysis has become more challenging. To address these challenges, new screening technologies with improved specificity are being implemented, allowing for the creation and adoption of targeted confirmatory analyses that produce more conclusive results. This paper outlines a six-step, data-driven, framework to develop and evaluate gas chromatography mass spectrometry (GC-MS) methods for targeted classes of drugs. The process emphasizes maximizing retention time differences (to minimize the potential for retention time acceptance windows to overlap) and understanding the trade-offs between sensitivity and reproducibility using a test solution containing pairs of compounds that are difficult to distinguish. The method is then evaluated by expanding the panel of compounds analyzed, identifying limitations in compound discrimination, comparing to current methods, and analyzing representative casework to establish usability. To demonstrate this framework, a method for synthetic cannabinoids was created. The developed method utilizes a DB-200 column and an isothermal temperature program. It was found that sensitivity could be adjusted, without compromising reproducibility, by altering the split ratio and injection volume. The targeted method successfully differentiated 50 cannabinoids based on either retention time differences or mass spectral dissimilarity - determined using a newly developed spectral comparison test. Compared to a general method used for casework, the targeted method was an order of magnitude more sensitive, a minute shorter, and provided major increases in retention time differences. This framework can be implemented and adapted to develop targeted methods for other applications or compound classes.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...

