Related Experiment Video
Updated: Nov 1, 2025

Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
Increased procedural safety of cryoballoon pulmonary vein isolation with a double 120 s freeze protocol
Lorenzo Bianchini1,2, Stefano Bordignon1, Shaojie Chen1
1Cardioangiologisches Centrum Bethanien (CCB)/Kardiologie, Medizinische Klinik III, Agaplesion Markus Krankenhaus, Akademisches Lehrkrankenhaus der Goethe-Universität Frankfurt am Main, Frankfurt am Main, Germany.
Background:
Recently a double 120 s freeze cryoballoon (CB) pulmonary vein isolation (PVI) protocol proved to be non inferior to a double 240 s freeze protocol in terms of atrial fibrillation (AF) recurrences. We hypothesized that this approach could also result in an increased procedure safety.
Methods:
Eighty consecutive patients treated with a double 120 s freeze protocol (Group CB120) were compared with 80 previous consecutive patients treated with a single 240 s freeze protocol (Group CB240). Procedures were performed with a temperature probe to monitor the luminal esophageal temperature (LET), using a cut off for cryoenergy interruption of 15°C. During ablation at the septal pulmonary veins (PVs), the phrenic nerve (PN) function was monitored by pacing.
Results:
In CB120 and CB240 the rate of single shot isolation was similar in all PVs. Time to isolation was not different between the two groups. Mean minimal esophageal temperature was lower in LSPV and LIPV of the CB240 group. A total of 4/80 patients (5%) of the CB120 group experienced a PN injury, but no persistent form was recorded; 11/80 patients (14%) of the CB240 group experienced a PN injury, three in a persistent form (p = .10). A LET <15°C was recorded in 3/80 patients (4%) in the CB120 group and in 16/80 patients (20%) in the CB240 group (p < .01). Composite rate of energy-related safety events (LET <15°C and PN injury) was significantly lower in the CB120 (34% vs. 9%, p < .01).
Conclusions:
Safety of second generation CB PVI can be increased using a double 120 s freeze protocol.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
06:48Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020