Trueness and precision of complete-arch photogrammetry implant scanning assessed with a coordinate-measuring machine
Marta Revilla-León1, Jeffrey Rubenstein2, Mohammed M Methani3
1Assistant Professor and Assistant Program Director AEGD Residency, Comprehensive Dentistry Department, College of Dentistry, Texas A&M University, Dallas, Texas; Affiliate Faculty Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Researcher at Revilla Research Center, Madrid, Spain.
Statement Of Problem:
Photogrammetry technology has been used for the digitalization of multiple dental implants, but its trueness and precision remain uncertain.
Purpose:
The purpose of this in vitro investigation was to compare the accuracy (trueness and precision) of multisite implant recordings between the conventional method and a photogrammetry dental system.
Material And Methods:
A definitive cast of an edentulous maxilla with 6 implant abutment replicas was tested. Two different recording methods were compared, the conventional technique and a photogrammetry digital scan (n=10). For the conventional group, the impression copings were splinted to an additively manufactured cobalt-chromium metal with autopolymerizing acrylic resin, followed by recording the maxillary edentulous arch with an elastomeric impression using an additively manufactured open custom tray. For the photogrammetry group, a scan body was placed on each implant abutment replica, followed by the photogrammetry digital scan. A coordinate-measuring machine was selected to assess the linear, angular, and 3-dimensional discrepancies between the implant abutment replica positions of the reference cast and the specimens by using a computer-aided design program. The Shapiro-Wilk test showed that the data were not normally distributed. The Mann-Whitney U test was used to analyze the data (α=.05).
Results:
The conventional group obtained an overall accuracy (trueness ±precision) value of 18.40 ±6.81 μm, whereas the photogrammetry group showed an overall scanning accuracy value of 20.15 ±25.41 μm. Significant differences on the discrepancies on the x axis (U=1380.00, P=.027), z axis (U=601.00, P<.001), XZ angle (U=869.00, P<.001), and YZ angle (U=788.00, P<.001) were observed when the measurements of the 2 groups were compared. Furthermore, significant 3-dimensional discrepancy for implant 1 (U=0.00, P<.001), implant 2 (U=0.00, P<.001), implant 3 (U=6.00, P<.001), and implant 6 (U=9.00, P<.001) were computed between the groups.
Conclusions:
The conventional method obtained statistically significant higher overall accuracy values compared with the photogrammetry system tested, with a trueness difference of 1.8 μm and a precision difference of 18.6 μm between the systems. The conventional method transferred the implant abutment positions with a uniform 3-dimensional discrepancy, but the photogrammetry system obtained an uneven overall discrepancy among the implant abutment positions.