Related Experiment Video
Updated: Nov 1, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Outcome of unstable pertrochanteric fractures in high-risk geriatric treated with external fixators
Yu Liang1, Shaojiang Liu2, Fenglin Zhong2
1Department of Orthopaedics, Panzhihua Municipal Central Hospital, Panzhihua, No. 34 on the Street of Yi kang, Panzhihua City, Province Sichuan, China. 545930442@qq.com.
Purpose:
To review the outcome of high-risk geriatrics with unstable pertrochanteric fractures treated with external fixator.
Methods:
Eighteen consecutive patients with pertrochanteric fractures were operated with external fixator by using closed reduction technique. AO type, accompanying diseases, operating time, transfused blood units, duration of hospitalization, complications, healing time and mortality were recorded. Patients were followed clinically and radiologically for two years at least. The Harris Hip Score was used to document hip function at each regular follow-up.
Results:
Fifteen patients with average age of 71.5 years were available for final evaluation. The mean operating time was 41.1 min and union was achieved in all cases with an average time of 16 weeks. The mean Harris Hip Score at one, three, six, twelve and twenty-four months post-operatively was 42.07 ± 8.55; 55.07 ± 11.62; 70.07 ± 10.32; 86.27 ± 9.06 and 89.27 ± 8.81 respectively. Complications included all the patients undergoing loss of some motion in the knee and four of them had to experience revision surgery because of knee stiffness, ten cases of pin-tract infections, seven cases of deep venous thrombosis, two cases of migration of the screws and two cases limb shortening.
Conclusions:
The use of external fixator in high-risk geriatric provided a satisfactory long-term efficacy, but the short-term functional results were quite unsatisfactory owing to high complication rate. Therefore, the advantages and disadvantages should be fully weighed when using external fixators, which was especially suitable for those patients who could not tolerate prolonged operative time and open surgery.
Level Of Evidence Iv:
Therapeutic study, level 4.
More Related Videos
08:20A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
Published on: March 24, 2019
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024