Related Experiment Video
Updated: Nov 1, 2025

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Inter-reader reliability of contrast-enhanced ultrasound Liver Imaging Reporting and Data System: a meta-analysis
Ji Hun Kang1, Sang Hyun Choi2, Ji Sung Lee3,4
1Department of Radiology, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri-si, Republic of Korea.
Purpose:
To systematically determine the inter-reader reliability of the contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS), with emphasis on its major features for hepatocellular carcinoma (HCC) and LR-M (LI-RADS category M) features for non-HCC malignancy.
Methods:
MEDLINE, EMBASE, and Cochrane databases were searched from January 2016 to March 2021 to identify original articles reporting the inter-reader reliability of CEUS LI-RADS. Meta-analytic pooled kappa values (κ) were calculated for major features [nonrim arterial-phase hyperenhancement (APHE), mild and late washout], LR-M features (rim APHE, early washout), and LI-RADS categorization using the DerSimonian-Laird random-effects model. Meta-regression analysis was performed to explore any causes of study heterogeneity.
Results:
Twelve studies with a total of 2862 lesions were included. The meta-analytic pooled κ of nonrim APHE, mild and late washout, rim APHE, early washout, and LI-RADS categorization were 0.73 [95% confidence interval (CI), 0.67 - 0.79], 0.69 (95% CI, 0.54-0.84), 0.54 (95% CI, 0.37-0.71), 0.62 (95% CI, 0.45-0.79), and 0.75 (95% CI, 0.64-0.87), respectively. Compared with the major features, LR-M features had a lower meta-analytic pooled κ. Substantial study heterogeneity was noted in the LI-RADS categorization, and lesion size (p = 0.03) and the homogeneity in reader experience (p = 0.03) were significantly associated with study heterogeneity.
Conclusions:
CEUS LI-RADS showed substantial inter-reader reliability for major features and LI-RADS categorization, but relatively lower reliability was found for LR-M features. In our opinion, the definitions of imaging features require further refinement to improve the inter-reader reliability of CEUS LI-RADS.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
09:23Author Spotlight: Enhancing Transplantation Research Through MicroCT Angiography in Murine Models
Published on: September 22, 2023
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography