Evaluation of the simplified carbapenem inactivation method as a phenotypic detection method for
Kageto Yamada1, Masakazu Sasaki1, Hinako Murakami2
1Department of Clinical Laboratory, Toho University Omori Medical Center, Japan; Department of Microbiology and Infectious Disease, Toho University School of Medicine, Japan.
Abstract:
Carbapenemase-producing Enterobacterales (CPE) have become a global health concern. Current molecular detection methods require special equipment and reagents. Thus, there is an urgent need for a highly sensitive, specific, and simple method for phenotypic detection of CPE in clinical microbiology laboratories. A simplified carbapenem inactivation method (sCIM) was recently reported. However, its utility for CPE detection has not been sufficiently evaluated to date. We evaluated the sCIM and compared it with the modified CIM (mCIM), using 133 CPE strains (producing IMP, 92; NDM, 11; NDM and OXA-48-like, 1; KPC, 13; OXA-48-like, 12; GES-24, 3; Nmc-A, 1) and 82 non-CPE strains (extended spectrum β-lactamase, 61; AmpC, 21). The sCIM was conducted by loading bacteria onto imipenem and meropenem disks. When imipenem disks with a 1+ bacterial load were used, the sensitivity and specificity of the sCIM were 97.0% and 100%, and those of the mCIM were 97.0% and 96.3%, respectively. The specificity of the sCIM decreased to 57.3% when the bacterial load on imipenem disks was increased to 2+. In contrast, when meropenem disks with a 1+ bacterial load were used, the sCIM had a lower sensitivity (78.2%) and an equivalent specificity (100%). When meropenem disks with a bacterial load of 2+ were used, the sensitivity and specificity of the sCIM increased to 96.2% and 93.9%, respectively. The diameter of the inhibition zone on meropenem disks was larger than that on imipenem disks, and the sCIM was less sensitive when meropenem disks were used. In addition, sCIM detection rates when using meropenem disks were particularly low for OXA-48-like producers (bacterial load 1+, 0/12; bacterial load 2+, 10/12). Our results indicate that the sensitivity and specificity of the sCIM was dependent on the bacterial load and that large bacterial loads led to false positives for AmpC and extended spectrum β-lactamase producers. Thus, the sCIM has high sensitivity and specificity for appropriate bacterial loads when imipenem disks are used.
More Related Videos
07:59Rapid and Specific Detection of Acinetobacter baumannii Infections Using a Recombinase Polymerase Amplification/Cas12a-based System
Published on: April 25, 2025
08:30One-day Workflow Scheme for Bacterial Pathogen Detection and Antimicrobial Resistance Testing from Blood Cultures
Published on: July 9, 2012