Related Experiment Video
Updated: Nov 1, 2025

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
A validated potentiometric method for the rapid determination of chromium ions content in food samples using a
Marwa El Badry Mohamed1, Eman Yossri Frag1, Heba A Marzouk1
1Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt.
Abstract:
Cr(III) has a vital role in the biological systems, and in many industrial and environmental processes, so the development of a selective, sensitive, and rapid method for its determination is a challenging goal. In this paper, an effective, selective, and inexpensive Cr(III) ions modified carbon paste electrode (MCPE) based on a simple ionophore named benazepril (BNZ) was developed and described. The proposed technique was validated using the EURACHEM guidelines. Our sensor shows a Nernstian slope of 19.20 ± 0.39 mV/decade in the range of 8.0 × 10-6-1.0 × 10-1 mol L-1with a quick response time (10 s) and can be applied for the measurements for at least 54 days with negligible change in the results. The proposed sensor has a stable potentiometric response in the pH range of 2.5-6.5 and has great selectivity towards Cr(III) ions over numerous inorganic cations. The Cr(III)-BNZ surface interaction was scrutinized by a scanning electron microscope (SEM). Lastly, the proposed electrode was applied for the determination of Cr(III) ions in various food samples, and the results were compared with the results of the inductively coupled plasma-optical emission spectroscopy (ICP-OES).
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
10:48Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...