Background:
Electromagnetic navigation bronchoscopy (ENB) is a navigation technology intended to improve the diagnostic yield of pulmonary nodules. However, nodule displacement due to respiratory motion may compromise the accuracy of the navigation guidance. The Veran SPiNDrive ENB system employs respiratory-gating (4D-tracking) to compensate for this motion. The aim of the present study was to evaluate the diagnostic performance and safety of the Veran SPiNDrive system for biopsy of pulmonary nodules.
Methods:
Adult patients with pulmonary nodules of ≥1 cm were enrolled at a single center. Both conventional bronchoscopy and 4D-tracking ENB were performed in one procedure session under general anesthesia, with the procedure order being randomly assigned. Radial probe endobronchial ultrasound and fluoroscopy were used in both groups. The diagnostic performance, safety, total procedure time, and total fluoroscopy time of the ENB phase were compared to the corresponding conventional bronchoscopy phase.
Results:
The study was terminated due to poor accrual; a total of eleven patients were enrolled. The mean size of pulmonary nodules was 2.1 cm. The sensitivity for malignancy was 67% (6/9) and 56% (5/9) with conventional bronchoscopy and with 4D-tracking ENB, respectively. Two cases developed minor bleeding after conventional bronchoscopy, while no complications were observed after 4D-tracking ENB. The mean procedure time was 16.1 and 21.7 min (P=0.090), and the mean duration time for fluoroscopy use was 77 and 44 sec (P=0.056) for the conventional bronchoscopy and the 4D-tracking ENB phases, respectively.
Conclusions:
The diagnostic performance of the Veran SPiNDrive 4D-tracking ENB did not exceed that of conventional bronchoscopy for pulmonary nodules. No complications were seen during 4D-tracking ENB. A study with a larger number of participants is required for further assessment.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...