Titration studies overestimate continuous positive airway pressure requirements in uncomplicated obstructive sleep
Olabimpe S Fashanu1, Rohit Budhiraja1, Salma Batool-Anwar1
1Division of Sleep and Circadian Disorders, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts.
Study Objectives:
Attended manual continuous positive airway pressure (CPAP) titration is the standard practice for determining optimal positive airway pressures for obstructive sleep apnea (OSA) treatment. However, an unattended single night auto-titrating positive airway pressure (APAP) titration is an alternative. The goal of this study was to determine whether therapeutic CPAP pressures determined during manual titrations are higher than APAP-generated surrogate pressures.
Methods:
We conducted a retrospective review of 165 adults with uncomplicated OSA who had full/split-night manual CPAP titrations prior to commencing treatment with APAP. Demographic and clinical data including 30-day APAP compliance data were obtained. We compared the recommended CPAP pressure from manual titrations with the 90th/95th percentile pressure generated from APAP usage over 30 days.
Results:
The recommended CPAP pressures during the manual titrations were higher than the 90th/95th percentile pressures generated from APAP (11.4 ± 3.4 vs 10.3 ± 2.4 cmH2O; P = .000). Almost half the group (41.9%) had their manually derived titration pressure at least 1.5 cm above the 90th/95th percentile pressure. In multivariate analyses, body mass index was the only variable that predicted higher manual titration pressures. Notably, the average residual apnea-hypopnea index on 30-day APAP data was less than the average residual apnea-hypopnea index observed at the recommended pressure during the manual titration (5.0 ± 4.3 vs 7.2 ± 8.5; P = .006).
Conclusions:
Manual CPAP titrations may overestimate pressure requirements, particularly in patients with higher body mass index, and may not be necessary in managing patients with uncomplicated OSA. APAP appears to be at least as effective as single-pressure CPAP, while delivering lower positive airway pressure.
Citation:
Fashanu OS, Budhiraja R, Batool-Anwar S, Quan SF. Titration studies overestimate continuous positive airway pressure requirements in uncomplicated obstructive sleep apnea. J Clin Sleep Med. 2021;17(9):1859-1863.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Sleep Apnea
The condition is more prevalent among...
Respiratory Volumes and Capacities I
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....